Siemens CFVS1415-LP Package contents, Dome camera parts, Installing the camera, Specifications

Page 2

English

Package contents

Dome camera

1 BNC connection cable

1 service monitor cable

1 remote PC connection cable (Additional RS232 cable is required to interface to your PC (not included))

Remote software CD

2 fixing screws

2 wall plugs

Fixing template

Installation and operating instructions (this document)

Dome camera parts

See figures A and B.

1.Cable entry holes

2.Unit casing

3.Dome casing

4.Zoom lever/locking screw

5.Focus lever/locking screw

6.Iris LEVEL screw

7.V phase adjustment screw

8.Mode setting DIP switches

9.PC connection port

10.Monitor output

11.Unit mounting holes

12.BNC connector

13.Power connector

14.Locking ring

15.Panning adjustment wheel

16.Axial ring

Installing the camera

Step 1: Connecting the cables

1.Connect the BNC cable to the BNC connector (12).

2.Connect the power supply cable to the power connector (13).

You can use 24 V AC or 12 V DC connection.

Caution

If using a DC supply, make sure the polarity is correct. Incorrect connection may cause malfunction and/or damage to the video camera.

3. Guide the cables through the cable entry holes (1).

Step 2: Mounting the camera

1.Place the template on the mounting surface and mark the holes.

2.Drill two holes as marked.

3.Insert the wall plugs into the holes.

4.Fasten the unit with the screws provided.

Step 3: Adjusting the camera position

1.Hold the lens so that it does not rotate.

2.Loosen the locking ring (14) and panning adjustment wheel (15).

Caution

Do not loosen the locking ring without holding the lens in place. Otherwise the lens may rotate with the locking ring and the cable may twist.

3.Turn the lens and axial ring (16) in the desired direction.

Note

If the camera does not rotate smoothly, loosen the locking ring completely. The locking ring has an internal stop and will not come off.

Caution

Do not turn the lens more than 360°, as this may cause internal cables to disconnect or break.

4.Lightly tighten the locking ring (14) and panning adjustment wheel (15)

Step 4: Adjusting zoom and focus

1.Loosen the zoom lever/locking screw (4) by turning it counter-clockwise.

2.Rotate the zoom ring to achieve the desired picture.

3.Loosen the focus lever/locking screw (5) by turning it counter-clockwise.

4.Rotate the focus ring to adjust the focus.

5.If readjustment is necessary, repeat the steps above.

6.Retighten the zoom lever/locking screw (4) and the focus lever/locking screw (5).

Caution

Retighten the locking screws to prevent loss of adjustment.

7.Hold the lens and tighten the locking ring (14) and panning adjustment wheel (15).

Optional settings

Adjust the brightness of the picture using the LEVEL screw (6):

L = low, makes the picture darker H =high, makes the picture brighter

Adjust the phase difference between cameras (use V Phase adjustment screw (7).

Set the DIP switches (8) to activate or deactivate the following features:

Backlight compensation (BLC)

Automatic gain control (AGC).

Automatically adjusts the picture to suit ambient brightness

Line Lock (LL).

Sets camera synchronisation to internal (OFF) or line lock (ON). Line lock is only available with 24 V AC.

The DC/AES DIP switch is not in use.

Step 5: Remote PC connection

This camera is equipped with the latest DSP technology. The remote software kit allows remote access and further enhances the camera’s usability and functionality.

Please install the remote software onto your PC in accordance with the "readme" file on the CD.

Note

Please read the camera’s parameters and save them to a file prior to performing any other adjustments. During this process the picture may flicker or distort. This is normal during this operation, and the picture will return to normal once the process is completed.

Additional camera functions include

Linear AGC gain control (18dB ~ 30dB)

Pedestal level adjustment (0~9 IRE)

Predefined BLC fields (6)

Sharpness (low/mid/high)

Day/Night transition level (adjustable)

Image Option (negative/monochrome)

Read camera parameters

Write to camera memory

Restore factory default settings

Save and reload parameters from file

Step 6: Attaching the dome to the unit

Note

Use a soft lint-free cloth to wipe the dome cover clean and remove fingerprints.

1.Clean the joint surfaces of the unit.

2.Place the dome on the unit (see figure C).

3.Turn the dome clockwise and lock the cover in place.

General guidelines

Operation and storage

Avoid filming very bright objects (such as light fittings) for an extended period.

Do not operate or store the unit in the following locations:

Extremely hot or cold places.

Close to sources of strong magnetism.

Close to sources of powerful electromagnetic radiation, such as radios or TV transmitters.

In humid or excessively dusty places.

Where exposed to mechanical vibrations.

Close to fluorescent lamps or objects reflecting light.

Under unstable or flickering light sources.

Cleaning

Use a soft, dry cloth to remove fingerprints or dust from the dome.

If the dome is very dirty, use a small amount of mild detergent on a damp cloth for cleaning. Ensure the dome is dry before attaching the dome to the unit.

Caution

Do not use volatile solvents such as alcohol, benzene or thinners. These solvents may damage the surface.

Transportation

Use the original packing material or materials of equal quality.

CCD characteristics

The following conditions may be observed when using a CCD camera. These are inherent in the design and do not stem from any fault within the camera itself.

Vertical smear: This phenomenon occurs when viewing a very bright object.

Patterned noise: This is a fixed pattern which may appear over the entire monitor screen when the camera is operated at a high temperature.

Jagged picture: When viewing stripes, straight lines, or similar patterns, the image on the screen may appear jagged.

Specifications

General

Power requirement

12 V DC or 24 V AC

 

(Min. 5 W)

Power consumption

3.5 W (max.)

Operating temperature

-10 to +50°C, 90% RH max.

Storage temperature

-20 to +60°C, 70% RH max.

External dimensions

112 x 97.5 mm

Weight

Approx. 0.3 kg

Unit material

ABS (30%) and polycarbonate

 

(70%)

Dome material

Polycarbonate

Imaging system

Imaging device

..................Exview™ Interline transfer ¼

 

inch CCD

Effective picture elements.PAL: 752(H) * 582(V)

TV system

PAL: 2:1 Interlace,

 

15.625 kHz horizontal,

 

50 Hz vertical

Optical system and other specifications

Day-Night Mode

Mechanical IR filter (automatic)

Focal length

f=2.8 to 5.8 mm

Maximum relative apertureF1.4

Viewing angle

Horizontal: 74.7° (wide angle) -

 

35.9° (telescopic)

 

Vertical: 55.2° (wide angle) -

 

26.9° (telescopic)

Minimum object distance ..

20 cm

Synchronisation system....

Internal or Line lock (24 V AC

 

only)

Horizontal resolution

480 TV lines

Minimum illumination

0.34 lx in C/L mode

 

0.15 lx in B/W mode

 

(AGC ON, more than 50% of

 

image output r=0.45, without

 

dome cover)

Video output

1.0 Vp-p 75 Ohm

Video S/N ratio

More than 50 dB (AGC OFF,

 

weighted)

White balance

Automatic (2500°K - 10000°K)

AGC

ON/OFF switchable

 

ON: 30dB gain

 

OFF: 18dB gain

BLC

ON (center measured) / OFF

 

switchable (6 zones with remote

 

software)

Information

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.

This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.

You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.

The shielded interface cable recommended in this manual must be used with this equipment in order to comply with the limits for a digital output device pursuant to Subpart B of part 15 of FCC rules.

© 2004 Siemens Building Technologies: Fire and Security Products

Data and design subject to change without notice.

Image 2