Rev 1.0
7.3
In the
・Valid only when the random trigger shutter mode is ON.
・MULTI signals can be input from the camera link I/F CC2.
・If exposure is executed several times before MULTI signal input, the images are output superposed. ・The exposure time is determined by the random trigger shutter mode setting and its determination method. ・The pulse width must be set to negative polarity and 1H (approximately 53.3μs) to 10 ms.
・FVAL is output in sync with the first LVAL after the end of MULTI signal input.
TRIG |
|
MULTI |
|
A | B |
CCD |
|
FVAL |
|
LVAL |
|
DVAL |
|
DATA OUT |
|
| A + B |
D4134176A