Toshiba CS8560D Switch setting, CCU rear-panel DIP SW, Initial factory setting All OFF

Page 30

[Switch setting]

(1) CCU rear-panel DIP SW

No.

Function

 

OFF

ON

 

 

 

 

 

 

 

 

 

GAIN selection

 

Factory-set

Manual GAIN

 

GAIN

1

 

 

 

 

O

 

 

 

 

 

 

 

1

 

adjustable

 

 

2

 

 

 

 

N

 

 

 

 

 

 

 

(GAIN)

 

GAIN

 

 

 

 

 

 

 

 

via GAIN

 

SHUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

2

E-shutter-speed

 

 

 

 

 

 

 

 

 

 

See shutter-speed table (Table 1)

 

 

4

 

 

 

 

 

3

 

 

 

 

 

 

 

 

(SHUT)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

VIDEO 5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Video output

 

1/60s non-interlace

1/120s interlace

 

SMODE

6

 

 

 

 

 

 

 

 

 

 

 

 

 

mode (VIDEO)

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Shutter mode

 

See shutter-mode table (Table 3)

 

PART

8

 

 

 

 

 

 

 

 

 

 

 

 

7

(SMODE)

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

Partial scan

 

See partial-scan table (Table 2)

 

EXP

 

 

 

 

 

 

 

0

 

 

 

 

 

9

(PART)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

RTS Exposure

 

FIX mode

PULSE W mode

 

 

 

 

 

 

 

 

(EXP)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes: *

Initial factory setting: All OFF

 

 

 

 

 

 

 

(Table 1) Electronic shutter-speed

Shutter-speed

No.2

No.3

No.4

OFF

OFF

OFF

OFF

1/200s

ON

OFF

OFF

1/500s

OFF

ON

OFF

1/1,000s

ON

ON

OFF

1/2,000s

OFF

OFF

ON

1/4,000s

ON

OFF

ON

1/8,000s

OFF

ON

ON

1/20,000s

ON

ON

ON

(Table 2) Partial-scan

Partial scan

No.8

No.9

OFF

OFF

OFF

Not acceptable

ON

OFF

1/2 partial

OFF

ON

1/4 partial

ON

ON

Notes : *Don’t set Electronic shutter-speed in OFF under RTS mode.

(Table 3) Shutter-mode

 

Shutter mode

No.6

No.7

SYNC

 

Random

 

V reset

OFF

OFF

 

 

 

 

SYNC reset

ON

OFF

Internal sync

trigger

 

 

Non-reset

OFF

ON

 

 

 

 

 

Not

acceptable

ON

ON

 

 

 

Random

 

Non-reset

OFF

OFF

Single VD

 

 

 

(Multiple shutter)

 

Ext. sync

 

 

 

 

 

trigger

 

Non-reset

ON

OFF

Consecutive VD

 

 

 

 

 

 

 

 

HD IN

 

 

V reset

OFF

ON

No VD

 

 

 

 

 

 

Restart / Reset

ON

ON

Single VD

 

 

Notes : * Under normal shutter mode partial-scan, set No.6,7 in OFF. **Under PULSE W mode, SYNC reset is disabled.

(2)CCU rear-panel SW

Function

SW

Selected Function

Ext. SYNC IN impedance

HIGH

HIGH impedance (Initial factory setting)

(HD/VD)

75Ω

75Ω

30

D4130891A

Image 30
Contents CCD Camera Model CS8560D Specifications D4130891AGraphic symbol definitions Indication Meaning This may cause fire and/or electric shockDo not repair, disassemble and/or modify by yourself Avoid short-circuiting signal output Use the specified power supplyTurn OFF the power in the case of connection Don’t place things or materials on the unitDisclaimer Limited Warranty D4130891A Product Description Exposure-time control via rear-panel DIP switch Camera adapter ·················· Model name CA170Rear DIP SW 120s 21 Interlace Video OUTEXT VD Sync reset mode Under internal sync Trig „ RTS Trig in notes 60s Non-interlaceExposure time is determined by VD interval Under other shutter modes OptionEven Field 10H Standard 11H 24H 30H 23.5H 31H Standard9H WEN OUT Option EXT VD EXT HD Timing is as follows 68H 448H120s 21 Interlace, ODD field ODD Feild120s 21 Interlace, Even field Even FeildBasic spec Internal sync specSync signal spec External sync specShutter trigger spec 1Operation mode Electronic shutter specPartial scan Video OUT Mechanical spec Ambient conditionConnector pin assignment Switch setting Initial factory setting All OFFCCU rear-panel DIP SW Optical black characteristics Relative Spectrum ResponseCAM Ext. VD Ext. HD phase difference ODD 1st field WEN timing aNormal shutter mode 60s Non interlace mode Under partial scan V-reset mode Standard120s Interlace mode ODD Field 120s Interlace mode Even FieldBRTS Non-reset mode Consecutive VD 1/60s Non interlace mode Under partial scan mode252.5H 10H DRestart / reset mode 1/60s Non interlace mode EXTERNAL-VIEW Drawing 41D4130891A