Nissin Di866 manual Manual Power Opertion, For Bracketing by Set button Press

Page 5
H appears at the upper right hand corner for High-Speed Sync

Manual Zoom Setting

The reflector position of Di866 can be set manually.

To get an illumination area different from the picture frame either wider or narrower field, manual zoom setting makes a sense. When using Di866 with non-dedicated camera or traditional film type camera, the reflector position of Di866 does not respond to the camera lens movement. In this case, use this Manual Zoom Setting.

On the TTL function screen, press the set button Set for 2 sec. TTL Advance page appears.

Select

M.Zoom and continuously select

on and

set Set

or wait for 8 seconds to returns to the TTL function

screen.

 

 

2nd (rear) curtain synchronization

Flash usually synchronizes to the camera shutter when it opens (1st curtain sync.). For the slow shutter photography, Di866 can be set the flash timing just before the shutter closes (2nd curtain sync.). By using this function, a moving subject is imaged with such moving marks behind. Refer the camera owner’s manual for details.

On the TTL function screen, press the Set

button for 2 sec.

TTL Advance page appears.

 

Select ‘Curtain’ by

button.

 

Select

‘2nd’ for 2nd Curtain Sync by

button.

Press the Set button or wait for 8 sec to return to the TTL function screen.

A symbol ‘>>>’ appears at the upper right hand corner for 2nd Curtain Sync, while no symbol appears for normal flash sync. (1st curtain)

15

Hi-Speed Sync

The flash of Di866 can be set for camera with higher shutter speeds up to 1/8000 second.

On the TTL function screen, press the Set button for 2 sec.

TTL Advance page appears.

 

Select ‘Hi-Speed’ by

button.

 

Select ‘On’ for High-Speed Sync by

button.

Press the Set button or wait for 8 sec to return to the TTL function screen.

A symbol

Flash Exposure Bracketing (FEB)

Di866 supports exposure bracketing function at every 0.3Ev increment within the range of 3Ev. You will get 3 continuous flash pictures in different exposure effects on each frame. Set the camera shutter for drive mode and number of picture frame is to be set on the camera. Refer the camera owner’s manual for details.

 

 

On the TTL function screen, press the Set

 

 

button for 2 sec.

 

 

TTL Advance page appears.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K

 

 

 

Select ‘Bracketing’ by

button.

 

 

 

 

 

 

 

 

 

 

 

 

 

Select ‘On’ for Bracketing by

 

 

 

button.

 

 

 

 

 

 

 

 

 

 

Select your favorite EV step from

 

 

 

0.3 to

 

 

 

3 for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bracketing by Set button.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press the

button or wait for 8 sec to return to the TTL function screen.

 

 

A ‘BKT1’ symbol appears at the upper right hand corner for Bracketing.

Remark:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMAGE ZONE (

Portrait,

Landscape,

Close-up,

Sports,

 

 

 

 

 

 

 

 

 

 

Night Portrait) When setting the camera mode to any of those image

 

 

 

 

 

 

 

 

 

 

zone, Di866 is automatically set at TTL-AUTO function mode. In this

 

 

 

 

 

 

 

mode, TTL exposure level compensation can not be adjusted. All other

 

 

 

 

advance functions are available.

 

 

 

 

 

 

16

Manual Power Opertion

The mode to be set on the camera:

or v

Flash Power can be adjusted manually at option. The photographer can set his desired exposure manually by the most appropriate power in combination with the aperture value set on the camera. 22 different power, from full power to 1/128 power, by every 1/3 stops are available.

Set the camera mode, to

or v on your camera.

 

 

 

 

 

 

 

 

 

 

Set the mode of Di866. From the 6 icons screen, select

 

 

 

 

 

M/Av and set Set .

 

 

 

 

 

 

 

 

Select

M and set Set .

 

 

 

 

 

 

 

 

Select

your desired power and set Set .

 

 

 

 

 

 

 

 

 

 

The camera-subject distance for the most proper exposure

 

 

 

 

 

 

 

 

is determined by the film speed (ISO) and the F stop set

 

 

 

 

 

 

on the camera.

 

 

 

 

 

 

 

 

This distance is shown in the Manual function screen.

 

 

 

 

 

 

The film speed information (ISO) is automatically

 

 

 

 

 

 

 

 

 

 

 

 

transferred from the camera.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The F. stop you set on the camera is to be set maunally on

 

 

 

 

 

 

 

 

 

 

 

the flash unit, too.

 

 

 

 

 

 

 

 

To get the camera-subject distance on the display screen,

 

9.0

 

 

F. Stop setting is required.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press set

Set

for 2 seconds, the screen goes to the

 

 

 

 

Advanced Function page.

 

 

 

 

 

 

 

 

Move cursor

to F.Stop line and continuously select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the same F.Stop number you set on your camera.

 

 

 

 

 

 

 

Press on/off switch to lock the value. (Press it again to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

release the lock)

 

 

 

 

 

 

 

 

The distance is automatically followed by changing the focal length and ISO sensitivity level on the camera, or selecting the other power level.

As for the non-dedicated or traditional type film cameras, the film speed (ISO) information is not transferred from the camera.

In this case, the film speed (ISO) is to be set on the flash unit to indicate the camera-subject distance.

Move cursor to ISO line at Advanced function page

and continuously select the ISO value to which you set camera. Press the set Set button.

or wait for 8sec. to return to M function screen.

17

18

Image 5
Contents Unique Function Digital TTL Power Zoom FlashSimple Operation Advanced FunctionsMenu Screen for Main Modes Safty InstructionsAdvanced Functions FE. LockFull Automatic Flash Control Setting the Mode and the FunctionBasic Operation Press it again to release the lock Advanced Custom SettingTTL Flash Exposure Value Compensation For Bracketing by Set button Press Manual Power OpertionHow to find SD or SF? Av. Mode OperationAvailable combination of flash models and cameras Where is the Remote flash sensor?AB C Remote flashCursor Netvigation Value Adjust Channel Select WirelessSingle Group Slave Flash Group a Setting Group SettingCustom settings Other FeaturesMy TTL TTL Exposure level custom setting Display Display can be set off if it’s not necessaryFlash Power Level Guide No. at manual exposure mode ISO 100 in meters/feetContinuously over Guide Number and Flash duration tableWarantee