Polycom Ceiling DocCam user manual Int

Page 15

26

 

 

 

 

 

Ceiling DocCam II — Appendix

 

 

 

 

 

 

 

 

Command Set

Command

Command Packet

 

Comments

 

 

 

 

 

 

 

 

 

CAM_Stablizer

On

81 01 04 34 02 FF

 

Vibration Correction

 

 

 

 

 

 

 

On/Off

 

 

 

Off

81 01 04 34 03 FF

 

 

 

 

 

 

 

 

 

 

CAM_Memory

Reset

81 01 04 3F 00 0p FF

p: Memory Number

 

 

 

 

 

 

 

(=0 to 5)

 

 

 

Set

81 01 04 3F 01 0p FF

 

 

 

 

 

 

 

 

 

 

Recall

81 01 03 3F 01 0p FF

 

 

 

 

 

 

 

 

 

 

CAM_Custom

Reset

81 01 04 3F 00 7F

FF

Starts in this mode at

 

 

 

 

 

 

 

Power on

 

 

 

Set

81 01 04 3F 01 7F FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recall

81 01 04 3F 02 7F

FF

 

 

 

 

 

 

 

 

 

 

 

CAM_Display

On

81 01 04 15 02

FF

 

Display On/Off

 

 

 

 

(81 01 06 06 02 FF)

 

 

 

 

Off

81 01 04 15 03 FF

 

 

 

 

 

 

(81 01 06 06 03 FF)

 

 

 

 

 

 

 

 

 

 

 

 

On/Off

81 01 04 15 10

FF

 

 

 

 

 

 

(81 01 04 06 06 10 FF)

 

 

 

 

 

 

 

 

 

CAM_Title

Title Set 1

81 01 04 73 00 mm nn pp

mm: Vposition,

 

 

 

 

qq 00 00 00 00 00 00 FF

nn: Hposition, pp: Color

 

 

 

 

 

 

 

qq: Blink

 

 

 

 

 

 

 

 

 

Title Set 2

81 01 04 73 01 mm nn pp

mnpqrstuvw: Setting of

 

 

 

 

qq rr ss tt uu vv ww FF

Display Characters

 

 

 

 

1st to 10th Character

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Title Set 3

81 01 04 73 02 mm nn pp

mnpqrstuvw: Setting of

 

 

 

 

qq rr ss tt uu vv ww FF

Display Characters

 

 

 

 

 

 

 

11st to 20 th Character

 

 

 

 

 

 

 

 

 

 

Title Clear

81 01 04 74 00FF

 

Title Setting Clear

 

 

 

 

 

 

 

 

 

 

 

On

81 01 04 74 02

FF

 

Title Display On/Off

 

 

 

 

 

 

 

 

 

 

 

Off

81 01 04 74 03

FF

 

 

 

 

CAM_Mute

On

81 01 04 75 02 FF

 

Mute On/Off

 

 

 

 

 

 

 

 

 

 

 

Off

81 01 04 75 03

FF

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/Off

81 01 04 75 10

FF

 

 

 

 

CAM_VPhase

Stop

81 01 04 05 00 FF

 

 

 

 

 

 

 

 

 

 

 

 

Up

81 01 04 05 02 FF

 

 

 

 

 

 

 

 

 

 

 

 

Down

81 01 04 05 03 FF

 

 

 

 

 

Up (Step)

81 01 04 08 2p FF

 

p=step (1-7)

 

 

 

 

 

 

 

 

 

 

Down (Step)

81 01 04 05 3p FF

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset

81 01 04 05 40

FF

 

Restore factory settings

 

 

 

Direct

81 01 04 45 00

00 0p 0q FF

pq: V-Phase (00-FF)

 

 

 

 

 

 

 

 

 

 

 

0 degree

81 01 04 25 00

FF

 

No Phase Turnover

 

 

 

180 degree

81 01 04 25 01

FF

 

Phase Turnover

 

 

 

 

 

 

 

 

 

Ceiling DocCam II — Appendix

 

 

 

 

27

 

 

 

 

 

 

 

 

 

Command Set

Command

Command Packet

Comments

 

 

 

 

 

 

 

 

 

 

 

CAM_PrivacyZone

SetMask

81 01 04 76 mm nn

mm: Mask Settings

 

 

 

 

 

 

0p 0p 0q oq 0r 0r 0s 0s FF

nn 00: Modify, 01: New

 

 

 

 

 

 

 

pp: X, qq: Y, rr: W, ss: H

 

 

 

 

 

 

 

 

 

 

 

Display

81 01 04 77 pp pp pp pp FF

Mask Display On/Off

 

 

 

 

 

 

 

 

pp pp pp pp : Mask

 

 

 

 

 

 

 

Settings (0: Off, 1: On)

 

 

 

 

 

 

 

 

 

 

 

SetMask Color

81 01 04 78 pp pp pp pp

pp pp pp pp: Mask

 

 

 

 

 

 

qq rr FF

Color Settings

 

 

 

 

 

 

 

qq: Color Setting when

 

 

 

 

 

 

 

0 is selected

 

 

 

 

 

 

 

rr: Color SEtting when

 

 

 

 

 

 

 

1 is selected

 

 

 

 

 

 

 

 

 

 

 

SetPan TiltAngle

81 01 04 79 0p 0p 0p

Pan/Tilt Angle Settings

 

 

 

 

 

 

0q 0q 0q FF

ppp: Pan

 

 

 

 

 

 

 

qqq:Tilt

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pp: Pan Speed

 

 

 

 

 

Move Pan Tilt

81 01 04 7A 0p 0p 0q 0q rs FF

qq:Tilt Speed

 

 

 

 

 

 

 

r 0: Stop, 1: Right,

 

 

 

 

 

 

 

2: Le ft

 

 

 

 

 

 

 

s 0: Stop, 1: Up,

 

 

 

 

 

 

 

2: Down

 

 

 

 

 

 

 

 

 

 

 

Set PTzMask

81 01 04 7B mm 0p 0p 0p

Pan/Tilt/Zoom Settings

 

 

 

 

 

 

0q 0q 0q 0r 0r 0r FF

for Mask

 

 

 

 

 

 

 

ppp:Pan, qqq: tilt

 

 

 

 

 

 

 

rrr: zoom

 

 

 

 

GridOn

81 01 04 7C 02 FF

Grid Display On/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

GridOff

81 01 04 7C 03 FF

 

 

 

 

 

 

 

 

 

 

 

 

CAM_KeyLock

Off

81 01 04 17 00 FF

Camera Control

 

 

 

 

 

 

 

 

Enable/Disbale

 

 

 

 

 

 

 

 

 

 

 

 

On

81 01 04 17 02 FF

 

 

 

 

 

 

 

 

 

 

 

 

CAM_IDWrite

 

81 01 04 22 0p 0q 0r 0s FF

pqrs: Camera ID

 

 

 

 

 

 

 

(=0000 to FFFF)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAM_ExternalLock

INT

81 01 04 55 00 FF

Internal Mode

 

 

 

 

 

Line Lock

81 01 04 55 01 FF

Line Lock mode

 

 

 

 

 

 

 

 

 

 

 

CAM_Alarm

On

81 01 04 6B 02 FF

Alarm On/Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

81 01 04 6B 03 FF

 

 

 

 

 

 

 

 

 

 

 

 

 

SetMode

81 01 04 6C pp FF

PP: Mode Settings

 

 

 

 

 

 

 

 

00 Focus Move Detection

 

 

 

 

 

 

 

(The rest position is fixed.)

 

 

 

 

 

 

 

01 Focus Move Detection

 

 

 

 

 

 

 

(The rest position is reset.)

 

 

 

 

 

 

 

02 AE Move Detection

 

 

 

 

 

 

 

(The rest value is fixed.)

 

 

 

 

 

 

 

01 AE Move Detection

 

 

 

 

 

 

 

(The rest value is reset.)

 

 

 

 

 

 

 

 

 

 

 

SetTime

81 01 04 6D 0p 0p FF

pp: Reset Time Setting

 

 

 

 

 

 

 

 

 

 

 

 

Alarm (Reply)

90 07 04 6B 01 FF

Detect Level

 

 

 

 

 

 

 

 

"Low" to "High"

 

 

 

 

 

90 07 04 6B 00 FF

Detect Level

 

 

 

 

 

 

 

 

"High" to "Low"

 

 

 

 

 

 

 

 

 

 

 

CAM_ExternalLock

INT

81 01 04 55 00 FF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LIne Lock

81 01 04 55 01 FF

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

Image 15
Contents Page Introduction Table of ContentsImportant safeguards UnpackingBNC to RCA Product overview Camera enclosureFront and back wall plate connections Remote InstallationBefore you install Mounting the cameraTo connect to the display device and control system Connecting cablesTo mount the camera To connect to the wall plateConfiguring for remote controls Programming presetsTo program a preset Viewing areas Using your codec remoteUsing your ClearOne remote OperationTroubleshooting SpecificationsAppendix Product Return and Repair WarrantyStandards to which Conformity is declared FCC Part 15/ICES-003 ComplianceEuropean Compliance EC Declaration of ConformityOverview of Visca Visca Communication SpecificationsVisca Command/ ACK Protocol RS-232 control informationNetwork Change Message Visca Camera-Issued MessagesError Messages ACK/Completion MessagesON/OFF CamwbATW CamaeINT Inquiry Command Comments Block Inquiry Command ListGain H Other Inquiry Commands ... Command Packet 8x 09 7E 7E 02 FF Byte Bit Comments Close Visca Command Setting ValuesExposure control Ntsc PALLens Control Zoom Ratio and Zoom Position for reference