Installing the Cable and Lens Subassembly
(for preOptiFused and bulk cable applications)
∙Feed the AmerGlow cable through the conduit leaving one foot of extra cable at each end.
∙If using bulk cable, assemble the lens subassembly as shown in the figure below.
⇒Terminate the cable using the OptiFusion process as described in the full instructions packed with the Photon Generator or OptiFusion Termination Kit. Any other process may dramatically reduce light output.
Seal nut
Compression nut
Grommet
| 1/16” |
| 1” |
FIBERworks lens housing | Spacer with |
(Invisible Gunite shown) | with Invisible Gunite and |
| Vinyl Liner lens housings |
Wide Angle | Standard | ||||||
Lens |
| Lens | |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Seal nut
| Lens retaining |
Lens | nut |
CAUTION
DO NOT use Optifusion gel on the wide angle lens. The gel will inhibit the light dispersion
capabilities of the lens and the lens will not perform as intended.
∙Make sure the lens
∙Continue feeding the cable until the lens assembly is about ½” away from the seated position.
∙Place the lens retaining nut onto the lens and PUSH the lens into place.
∙Hand tighten the lens using the lens tightening tool until the
⇒For Standard Gunite and Fiberglass lens housings (which do not use the spacer and spacer o- ring), hand tighten the lens retaining nut ¼ turn past the seated
⇒For Invisible Gunite and Vinyl Liner housings (which use the spacer and spacer
CAUTION |
DO NOT over tighten lens retaining nut. Damage to lens assembly may result in
leakage of pool water into conduit.
Save These Instructions
4/04/02 | Instruction P/N 99293000 | Rev B |
Pentair Pool Products
1620 Hawkins Ave., Sanford, NC 27330 ~ (919)
10951 West Los Angeles Ave., Moorpark, CA 93021 ~ (805)