Flash Tube Replacement
Ensure that the unit is switched off and disconnected from the mains supply and then wait thirty minutes before touching / removing flashtube.
Remove the protective cap and unwind the twisted Trigger wire from the flashtube support.
Gently pull the flashtube assembly out of the unit.
To replace the assembly, hold the flashtube as shown and taking care to support both legs of the tube, gently but firmly, push the flashtube into position, and wind the Trigger wire around the flashtube support.
Always replace with the correct flashtube assembly,
Travel-Pak
The Esprit Gemini is great in the studio, but what if you need to work on location?
Thanks to this handy battery pack, your Bowens Esprit Gemini Monoblocs can leave the studio to go on location anytime, anywhere!
Able to power two monoblocs simultaneously with a total power of up to 1500w/s, the
With a fast/slow charge option to prolong battery life as well as a stylish carry bag offering protection from the elements and up to 3 inches of water, no location photographer should be without this unique power pack.
Dimensions - 180(l) x 120(w) x 175(h)mm Weight - 4.1kg
Also available for the Bowens
Bowens Universal 2Amp SLA Charger. |
8www.bowens.co.uk
Connecting & Using the Esprit Gemini
The Esprit Gemini unit may be operated either on a mains supply or with a Bowens battery source such as the Bowens
!!! WARNING HIGH VOLTAGE !!!
NEVER CONNECT THE ESPRIT GEMINI TO BOTH A MAINS SUPPLY AND A BATTERY SUPPLY AT THE SAME TIME.
THIS APPLIANCE MUST BE EARTHED WHEN USED WITH MAINS. DISCONNECT THE MAINS LEAD, WHEN CHANGING MODELLING LAMPS & FLASH TUBES.
For mains operation, the mains switch (page 4) should be in the upper position. For battery operation the switch should be in the lower position.
The centre position is OFF.
NOTE: When operated from a battery source, the modelling functions are not available.
Ensure the power source is Off.
Connect the unit using the appropriate cabling.
If using a battery source, ensure the connector locks are fully tightened. Switch the power source on, then switch on the Esprit Gemini.
The unit will charge and indicate it is ready for use by illuminating the Green READY light. Press the TEST button to check the unit fires.
Mounting
Mount the Esprit Gemini unit on selected support system.
The mounting bush on the 'L' bracket allows for two possible ways of mounting to the stand / support (Fig.3). Method B may be found useful if the light is required to point down.
Figure 3
A | B |
www.bowens.co.uk 5