Operating Manual - NE Two Channel Power Amplifiers
ne1600 Models |
| ne1600 |
| ne1600.10 | ne1600.70 | |||||
RATED | RATED | RATED | RATED | RATED | RATED | RATED | RATED | RATED | ||
| ||||||||||
| WATTS | VOLTS | LOAD Ω | WATTS | VOLTS | LOAD Ω | WATTS | VOLTS | LOAD Ω | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
| 800 | 100 | 12.5 | 800 | 70 | 6.1 | |
Stereo Mode | 450 | 60 | 8 | 512* | 64* | 8* | 613 | 70 | 8 | |
Both Channels Driven | ||||||||||
800 | 56.6 | 4 | 256* | 32* | 4* | 522* | 45.7* | 4* | ||
20Hz - 20KHz 1% THD | ||||||||||
| 400* | 28.3* | 2* | 128* | 16* | 2* | 261* | 22.9* | 2* |
Bridged Mode
1600
113
8
1600
200
25
1600
140
12.3
ne2400 Models |
| ne2400 |
| ne2400.10 | |||
RATED | RATED | RATED | RATED | RATED | RATED | ||
| |||||||
| WATTS | VOLTS | LOAD Ω | WATTS | VOLTS | LOAD Ω | |
|
|
|
|
|
|
| |
Stereo Mode |
|
|
| 1200 | 100 | 8.3 | |
700 | 74.8 | 8 | 1152* | 96* | 8* | ||
Both Channels Driven | |||||||
|
|
|
|
|
| ||
20Hz - 20KHz 1% THD | 1200 | 69.3 | 4 | 576* | 48* | 4* | |
| 600* | 34.6* | 2* | 288* | 24* | 2* | |
Bridged Mode | 2400 | 139 | 8 | 2400 | 200 | 16.7 |
*Values indicated by an asterisk are intended as guidelines only. Amplifier is not rated for this load impedance and may
All NE two channel power amplifiers come standard with XLR and Euroblock input connectors, and Speakon/ Euroblock output connectors. All models include balanced analog inputs, bridge mono mode, an 80Hz
All NE two channel amplifiers also include Analog Aux Outputs on XLR and Euroblock connectors. The Aux Outputs are buffered signals taken just before the power amplifier driver stage. If there is no DSP capability installed in the amplifier, the Aux Outputs are simply a buffered signal matching the inputs. If the amplifier has DSP installed however, each Aux Output can be independently configured, in addition to the two main amplifier channels, with its own DSP processing and any input source, including AES/EBU or CobraNet (if installed) to drive other power amplifiers.
Additional options are available for the NE two channel power amplifiers including the following:
1)Internal DSP Processing - With this factory installed option, and using Proteane (network enabled) software, each amplifier input channel can be configured with pluggable DSP blocks to have its own dynamics control, gain functions, graphic and/or parametric EQ,
Presets can be used to store and retrieve global parameters of an amplifier’s control surface and DSP section from a file. In addition, Sub Presets allow for a collection of individual DSP function parameters within and across both channels of an amplifier to be stored and recalled as a set, affecting only those parameters which have been tagged. Up to 35 presets/subpresets can be stored within the amplifier, and can be recalled in real time via Ethernet from a computer using Proteane software.
2)AES/EBU Input - Using an optional input card, NE two channel amplifiers can accept AES/EBU digital inputs. This protocol allows 2 channels of digital audio to be transmitted over a single cable, thus maintaining a completely digital signal path until just before the power amplification stage. 48kHz & 96kHz data rates are supported.
3)Network Digital Audio (CobraNet) - This option allows the NE two channel amplifier to be part of a net- worked audio distribution system. CobraNet is a technology developed and supported by Cirrus Logic (www.cirrus.com). It is a combination of software, hardware and network protocol which allows distribution of multiple channels of real- time, high quality digital audio over a standard Ethernet Network. For detailed information about CobraNet or its implementation visit www.cobranet.info.
4