take a closer look
Password protection prevents unauthorized use of the configuration utility.
The dome incorporates an innovative twist lock release from the mounting base for easy installation and servicing.
The fully isolated power supply helps eliminate ground loops.
Users can set
Vertical sync phase adjustment is provided to help compensate for different phases of power when
Sensing of 50/60 Hz lines is automatic and does not require manual adjustment.
Surge protection is provided for video, code, alarms and power connections.
Daisy chain configuration of control wiring is enabled:
-For
-For SensorNet: 32 devices at a maximum distance of 1 km (3000 ft) on one 22 AWG unshielded twisted pair (UTP)
-For Manchester: 3 domes at a maximum distance of 1500 m (5000 ft) on one 18 AWG shielded twisted pair (STP)
-For
The features of the SpeedDome Ultra VII with EIS can be extended to outdoor environments via the SpeedDome Ultra Outdoor Housing. The outdoor housing, designed especially for the SpeedDome Ultra’s small, unobtrusive size, makes it the perfect protection for the dome. The housing now features a reinforced outdoor housing as standard and a heavy duty vandal resistant housing kit option.
Two Mounting Base Options
The housing/eyeball assembly twist locks into both
mounting bases. The I/O board base connects the
housing/eyeball assembly in one step. Power, communication
and video cables (or composite cable) are connected one
time to an I/O PC board in the mounting base, so the
assembly is simply twist locked onto the base. Service
and maintenance are easy and can be accomplished
without a ladder or lift via the installation/removal tool. The
I/O board mounting base supports four alarm inputs and
four alarm outputs as well as power and communication LEDs. The standard base connects the housing/eyeball assembly in two steps. First, power, communication and video cables (or composite cable) are inserted through the base and attached to the assembly. Then the assembly is connected to the base. The standard mounting base supports one alarm input and one alarm output. The installation/removal tool cannot be used to install this configuration.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
with I/O Board |
| with Flying Lead |
| ||||||
Mounting Base |
| Mounting Base |
| ||||||
|
|
|
| (Pigtail) |
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
| ||||||||
N U M B E R O F P R E S ET S | |||||||||
Controller or |
|
|
|
|
|
|
| ||
Matrix Switcher |
| Protocol |
| Number of Presets | |||||
ADTT16E |
| SensorNet |
| 96 |
| ||||
|
|
|
|
| 4 |
| |||
MegaPower LT |
|
|
| 96 |
| ||||
|
|
|
| SensorNet |
| 96 |
| ||
AD2150 |
| Manchester |
| 64 |
| ||||
|
|
|
|
| 16 |
| |||
MegaPower 48 and |
| SensorNet |
| 96 |
| ||||
MegaPower 48 Plus |
| Manchester |
| 64 |
| ||||
|
|
|
|
| 96 |
| |||
VM96 |
| SensorNet |
|
| Unlimited | ||||
|
|
|
|
|
| Unlimited | |||
MegaPower 168 |
| SensorNet |
| 64 |
| ||||
|
|
|
| Manchester |
| 64 |
| ||
|
|
|
|
| 64 |
| |||
|
|
|
|
| 16 |
| |||
MegaPower 1024 |
| Manchester4 |
| 64 |
| ||||
|
|
|
|
| 16 |
| |||
Third party interfaces |
|
| 96 |
| |||||
|
|
|
|
|
|
|
|
|
|
2Using
3Using
4Using Manchester Code Distributor (model number AD2091)
1This distance is for the