Allied International GX3300C manual Adjusting the F-mount

Page 17

Adjusting the F-mount

THE F-MOUNT IS ADJUSTED AT THE FACTORY AND SHOULD NOT REQUIRE ADJUSTING.

If for some reason, the F-mount requires adjustment, use the following method.

Attach F-mount compatible lens

Use an F-mount compatible lens that allows an infinity focus. Attach the lens to the camera using a counter-clockwise rotation of about a quarter turn. The lens should snap into place and the lens flange and camera flange should mate over the full circumference.

Loosen F-MOUNT FRONT ASSEMBLY

Use a 1.5mm hex wrench to loosen the 3 set screws which hold the F-mount front assembly to the camera body.

Image to Infinity

Set the lens to infinity and image a distant object. The distance required will depend on the lens used but typically 30 to 50 feet should suffice. Gently move the F-mount front

GX3300 Technical Manual

Page 17

Image 17
Contents GX3300 / GX3300C Table of Contents Legal notice Contacting Allied Vision Technologies Introduction PrecautionsWarranty GX3300 Technical Manual Specifications Supported Features GX F-MOUNT MechanicalConnections GX Connection DiagramGeneral Purpose IO Port AS Seen from Back of Camera PIN FunctionExternal Power 8mA 500 32mW 14 µs GPO Lens Control Port AS Seen from Back Camera Do not Contact Clean Sensor Unless Absolutely Necessary Cleaning the SensorAdjusting the F-mount GX3300 Technical Manual Network Card Configuration GX3300 Technical Manual GX3300 Technical Manual GX3300 Technical Manual GigE Viewer application window GigE Sample Viewer and Filter DriverTrouble Shooting Ipconfig /all screenshot Saving camera setting file Addendum 3V Logic GX IO SchematicCircuit User Trigger Circuit ExampleLensZoomConnection Iris VideoTrigger Timing Diagram GX3300 Technical Manual GX3300 Technical Manual Camera Controls