Sony TS-DSC-S40-01 manual Auto Walk-Test mode on power up, Adjusting the PIR Sensitivity POT

Page 4

TrackSnap Manual

Model TS-DSC-S40-01

Auto Walk-Test mode on power up

When turning power on to your TrackSnap both the red and green LED will light up. They will both stay on for 30 seconds. This time will allow the PIR circuit to warm up. After this time expires the green LED will turn off and the red LED will blink 5 times letting you know that the board is entering a 1 minute automatic walk- test phase. At this point you can move around the camera setup and check out the PIR area. Both the green and red LED’s will light when motion is detected. After the 1 minute automatic walk-test phase expires the red LED will blink 5 times letting you know the camera system will now become active.

Adjusting the PIR Sensitivity POT

To adjust the PixController PIR detection range simply turn the single turn POT shown to the left to your desired range. The default setting is in the middle, as shown. The two “dots” on the Philips head screw show the actual location.

The default setting is desirable for almost all weather conditions. In very hot summer months, or setups over fields with no shading cover you should reduce the PIR sensitivity.

Note: Turning the sensitivity to the minimum setting will turn the PIR detection off.

Adjusting the Day/Night Cal. POT

When adjusting the Day/Night Sensor POT you must first set the DIP switches 3 & 4 “Up” when the board is powered down, and then turn the board on. The “Red Control LED” will light up when the detection level detects darkness. You may want to adjust this in the darkest setting you want to run your system at when adjusting this POT. When finished you will need to return DIP switches 3 & 4 back to their original setting.

Version

Page 4 of 12

Draft

TS S40.01

This document comprises information provided by Suppliers and is

 

 

assumed to be correct.

 

Image 4
Contents TrackSnap Manual Sony DSC-S40 TrackSnap Setup Tips IntroductionPIR Motion Sensors Basic Overview for Effective Use PIR Sensor Detection AreaAdjusting the PIR Sensitivity POT Auto Walk-Test mode on power upAdjusting the Day/Night Cal. POT Switch PIR DelayMode Picture Mode Camera ModeCamera Original LE Camera LERecording Time Day, Night, or 24 hour operation setting Professionally built, assembled, and testedDraft Mounting the PIR Lens Fast Re-Trigger PIR detection electronicsLE Board Mounting PIR Sensor Considerations Pelican 1060 Micro CaseSony DSC-S40 Camera Settings and Specifications LensSymptom Cause TroubleshootingSolution