Samsung SVD-4700 manual Iris Auto Shutter AGC High SSNR3

Page 16

Operating Your Camera

direction of the Function Setup Switch and then press the Function Setup Switch. Increase or decrease iris level by moving the left or right direction of the Function Setup Switch while verifying the changes on screen.

 

 

 

 

 

 

 

 

 

IRIS AUTO SETUP

 

 

 

IRIS MANUAL SETUP

 

 

OPEN LIMIT 938

 

 

 

IRIS F-No

F1.6

 

 

CLOSE LIMIT 1

 

 

 

IRIS MAN 1023

 

 

RETURN

 

 

 

RETURN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SHUTTER : Control image brightness by adjusting shutter speed.

Position the indicator over 'SHUTTER' by moving the up or down direction of the

Notes

Image may become unstable if the camera is set to 'ESC' mode and faces a strong fluorescent light.

Under 'ESC' mode, the brightness can be adjusted by moving the left or right direction of the Function Setup Switch

AGC (Auto Gain Control) : For brighter images.

Position the indicator over 'AGC' by moving the up or down direction of the Function Setup Switch.

Set 'AGC' to the desired mode by moving the left or right direction of the Function Setup Switch.



Function Setup Switch. Then select the desired shutter mode (A.FLK, ESC, MANUAL)

by moving the up or down direction of the Function Setup Switch.

EXPOSURE SETUP

BRIGHTNESS 50

IRIS

AUTO

SHUTTER

---

AGC

HIGH

-MANUAL : Manual shutter speed setting.

-A.FLK (NTSC: 1/100, PAL: 1/120) : Flicker-free mode.

-ESC : Automatic shutter speed setting (optimal).

-HIGH : Wide range gain value adjustment

-MANUAL : Selecting gain value range. (5dB ~ 41dB)

-OFF : Disabled

-LOW : Narrow range gain value adjustment

-MEDIUM : MEDIUM range gain value adjustment

EXPOSURE SETUP

BRIGHTNESS 50

IRIS

AUTO

SHUTTER

---

AGC

HIGH

SSNR3

ON

GAIN MANUAL SETUP

AGC VAL

5dB

RETURN

 

Auto operation is possible only when the IRIS is set to MANUAL. SSNR(Samsung Super Noise Reduction) : On screen noise reduction.

If you choose ’MANUAL‘, select the optimal shutter speed.

-In MANUAL mode, the optimal shutter speed needs to be designated. Select from 1/60 to 1/120,000

(NTSC) or from 1/50 to 1/120,000 (PAL). * 'Sens-Up' mode can be configured manually (2x to 512x).

-Verify changes made to the shutter speed by referencing to changes the 'on-screen' brightness.

Press the Function Setup Switch to complete.

SHUTTER MANUAL SETUP

SHUTTER VAL

1/50

RETURN

 

Position the indicator over 'SSNR3' by moving the up or down direction of the

Function Setup Switch.

Set 'SSNR3' to the desired mode by moving the left or

right direction of the Function Setup Switch.

 

SSNR

- OFF : Disabled

LEVEL

12

 

RETURN

 

 

 

 

COLOR DOME CAMERA 30 User Guide

COLOR DOME CAMERA 31 User Guide

Image 16
Contents English Thank you for purchasing a Samsung CCD Camera SVD-4700PContents FeaturesPrecautions May cause a product malfunction※ The set for America does not include the power adapter Components and AccessoriesOverview Installation InstallationPlease turn off the power when connecting ConnectionControl Cable EnableRET PKT Operating Your Camera Main Setup Ssdr White BALBacklight Mask tone areaMotion Detection Motion DET SenstivityFocus Mode Auto Focus Setup ModeUser Preset Zoom TrackExposure Iris Auto Shutter AGC High Iris Auto Shutter AGC High SSNR3Special Setup Privacyoff DAY/NIGHT Auto SpecialArea SEL You can select up to 12 MD areas GraySpecial Setup Privacy ※ When AGC is middle modeSync Comm ADJ Image ADJ SwitchScreen Comm ADJ Image ADJ Monitor Display Return CAM TitleReset To reset your camera to factory default conditionTo finish setup menu ExitTroubleshooting SpecificationsDimension SSNR3European Representative Name Equipment Type/EnvironmentSales Network