Panasonic wv-cp500, WV-CP504 manual WV-CP500, Functions Alarm input

Page 18
120V ~ 60Hz
ALARM OUT (Alarm output)
GND
ALARM IN (Alarm input)
The external terminal is the same between WV-CP500 and WV-CP504.
ALARM OUT POWER
GND
ALARM IN

External synchronization switch

The settings of the alarm input/output are configured on the SETUP menu. Refer to the network operating instructions (PDF) for further information.

Important:

• Be sure to turn off the power of each device before connection.

Alarm output

Input specification: Open collector out- put (max. voltage: 16 V DC)

Off: Internally pulled up 2 V to 4 V DC

On: Output voltage 1 V DC or less (max. drive current: 100 mA)

Functions: Alarm output Black-and-white switching output

WV-CP500

VIDEO OUT

Alarm input

Input specification: No-voltage make contact input (3 to 5 V DC, internally pulled up)

Off: Open or 3 to 5 V DC

On: Make contact with GND (required drive current: 0.2 mA or more)

Functions: Alarm input

VMD enabling input

Color/BW switching input

Scene file switching input

*When an external device is connected, exercise care to avoid exceeding the rating.

*Applicable wire: 22 AWG-28 AWG, solid wire/stranded wire

Strip the end 9 mm to 10 mm {11/32" to 13/32"} of the wire and

Stripped

insert it.

9 mm - 10 mm

{11/32" to 13/32"}

18

Image 18
Contents WV-CP504 This apparatus must be earthed Important safety instructions Disclaimer of warranty Limitation of liabilityIntroduction of SUPER-D5 super dynamic function Introduction of newly developed high-resolution CCDPreface Auto back focus function ABF equippedTrademarks and registered trademarks Contents Precautions Major operating controls and their functions Side view WV-CP500Rear view WV-CP500 Power indicator ALC lens connectorVideo output connector External terminal Power connector only for WV-CP500Precautions for installation Power cord only for WV-CP500 Installation and connection Rotate the lens option clockwise slowly to mount the lensLens type Model Nos Secure the camera mount bracket Option to an installation position, Installation sample on a ceiling Mount the camera on the camera mountPage Coaxial cables Functions Alarm input WV-CP500Turn on the power WV-CP504AC 24 DC 12 To use the varifocal lens/zoom lens Adjust the focusHow to adjust the back focus To use a fixed-focal lensPage Setup menu Setup item DescriptionLanguage Basic operation StepRET TOP END Screen transition diagram Troubleshooting Cause/solutionReference Pages Specifications GeneralCamera Standard accessories ALC/ALC+/ELCPage Panasonic System Solutions Company Panasonic Canada IncPanasonic Sales Company Panasonic Puerto Rico, Inc