STANDARD INSTALLATION PROCEDURE, MV6W

CONTENTS INCLUDE:

(1)Wall mount Bracket

(1)Dome base

(1)Dome

(1)Dome liner

(1)Camera swivel plate

(1)Camera mount with camera, lens, and PC Board

(1)Camera adjustment arm

(1)Camera adjustment template

(2)4-40 x 1/4" screws

(1) 8-32 x 3/8" screw

INSTALLATION

1. Locate the area on the wall where the bracket is to be mounted. Cut a hole no larger than 1" in diameter and feed the necessary wires/cable through (Figure 1).

2. Feed wires/cable through the hole in the back side of the bracket and out through end of the pipe.

3. Attach the bracket to the wall with fasteners that best fit the application.

Figure 1

HOUSING INSTALLATION

1. Once the bracket is secure, feed all wires/cable through the top dome. Slide the top dome onto the bottom of the bracket; the grommet should be secure around the bracket pipe (Figure 2).

GROMMET

TOP DOME

2. Once the top dome has been placed on the bracket, feed all wires/cable through the 3/4" conduit connector and camera housing.

3. Slide the housing onto the bracket, then tighten down the screw on the 3/4" conduit connector (Figure 3).

Note: The connector will need to be tightened completly down to secure the housing to bracket.

4. Once the housing has been secured to the bracket, slide the top dome back down along the bracket until it fits on top of the housing. The grommet will keep the top dome in place.

3/4" CONDUIT CONNECTOR

Figure 3

Make necessary camera adjustments and complete the installation process as specified elsewhere in these instructions.

PCF6W, PCV6W Dimensions

 

3.4"

7.0"

3.3"

5.4"

10.8"

 

Figure 2

- 4 -

Image 4
Contents Top Dome EMT Clamp Connector Housing Liner Standard Installation Procedure Contents IncludeInstallation Attaching Housing PCF6/PCV6 Pendant MountDome Replacement Camera AdjustmentBase TabsAGC ELCStandard Installation PROCEDURE, MV6W Contents Include Housing InstallationImportant Safeguards Safety PrecautionsService Electrical SHOCK, do not Expose