Schneider Electric EM4800 manual Display Navigation, Normal Mode, Diagnostics Mode

Page 10

PowerLogicTM EM4800 Series

 

930-112-01-B.00

PowerLogic configuration tool

 

01/2011

 

 

Display Navigation

The display on the front of the meter provides status information for each

 

circuit, and general information for metering. The PowerLogic EM4800 meter

 

has three buttons for navigating: a Display button, and left and right arrow

 

buttons. The display has a normal and a diagnostics mode.

 

Normal Mode

 

In Normal mode, the Display button scrolls through the information for each

 

meter. The left and right arrow buttons select the previous or next meter

 

points respectively. The following information is available:

 

Real Energy Delivered kWh D

 

Real Energy Received kWh R

 

Real Power Watts

 

Reactive Energy Delivered KVarhD

 

Reactive Energy Received KVarhR

 

Reactive Power Var

 

In Normal mode, the right and left arrow buttons scroll the display from meter

 

points 1 to 8, 1 to 12, or 1 to 24, depending on your configuration.

 

Diagnostics Mode

 

Diagnostics mode is accessed by pressing and holding the Display button for

 

5 seconds. In Diagnostics mode, pressing the Display button will scroll

 

through the following additional information:

 

Send data command

 

CT Primary value and Real Power Watts per phase

 

Voltage per phase

 

Local IP address

 

Reset factory default IP address command

 

Date and time (UTC)

 

In Diagnostics mode, the right and left arrow buttons scroll the display from

 

meter 1 through N. When the local IP address is shown on the LCD, use the

 

right and left arrow buttons to scroll through the following information:

 

Remote host server IP address

 

Time server IP address

 

Default IP address

 

Default NetMask

 

Default gateway

 

PPP user name

 

Phone number

 

AT command string

 

Alternate phone number

 

Unit serial number

 

Firmware build number

 

Ethernet port MAC address

 

Firmware revision

 

Potential transformer ratio

4

© 2011 Schneider Electric All Rights Reserved

Image 10
Contents PowerLogicTM Series EM4800 Procedure PowerLogicTM EM4800 Series 930-112-01-B.00 01/2011PowerLogicTM EM4800 Series PowerLogicTM EM4800 Series 930-112-01-B.00 01/2011 Table of Contents Schneider Electric All Rights Reserved EM4805 meters Configuration tool supports the PowerLogic EM4833, EM4880Configuration and Programming PointProgramming access to meter parameters Parameter Read access Write access Activation timeManufacturing Meter and probe pointsDiagnostics Mode Normal ModeDisplay Navigation Direct Connection Ethernet Requirements Communications ConnectionsInjury Network Connection Ethernet Requirements Login Used with meters on a different network Available for configuration. See FigureTo connect to a meter on the same network Proceed to Unit Field Configuration Tab on Discovered Units dialog boxConfiguration tab Unit Field Configuration tab parameters Field Parameter DescriptionReport Parameters 930-112-01-B.00 Parameter Description By selecting the check box930-112-01-B.00 You can set the display format to IEC You can set the BACnet device ID by PowerLogic EM4805 PowerLogic EM4833 PowerLogic EM4880 List of supported metering configurationsManufacturing Tab Meter Points Circuits Tab Meter Point ConfigurationSee Completing the Meter Configuration on To change the Current, enter the required number. To changeBadge Numbering Badge Numbering pane Pulse Probes Tab Completing the Meter Configuration EM4800 Series meter is ready to be programmedSending the configured settings to the meter Window. See Figure930-112-01-B.00 01/2011
Related manuals
Manual 40 pages 36.12 Kb

EM4800 specifications

Schneider Electric, a global leader in energy management and automation, offers advanced power monitoring solutions that enhance energy efficiency and operational effectiveness. The EM4800 and EM400 series are prominent products in Schneider Electric’s energy monitoring line, designed specifically for efficient energy consumption management in various industrial and commercial applications.

The EM4800 is a comprehensive energy meter that caters to larger facilities and energy-intensive operations. One of its main features is its ability to monitor multiple electrical parameters, including voltage, current, frequency, power factor, and total active/reactive energy. The device supports diverse communication protocols such as Modbus, Ethernet, and BACnet, allowing seamless integration into existing building management systems. This diversity in communication enhances visibility into energy usage and supports real-time monitoring, enabling facility managers to make informed decisions.

On the other hand, the EM400 series is designed for smaller applications while still delivering robust functionality. This series is tailored for monitoring power consumption in smaller commercial buildings or branch offices. EM400 meters focus on essential energy metrics but do so with a compact, easy-to-install design. With features like demand forecasting and peak load management, the EM400 provides valuable insights that help organizations optimize their energy usage.

Both models come equipped with advanced technologies such as harmonic analysis, which is crucial for understanding power quality and mitigating potential risks associated with harmonic distortion. The user-friendly interface of these devices facilitates quick access to energy data, making it simple for users to analyze consumption patterns and identify opportunities for energy savings.

In concurrence with Schneider Electric’s commitment to sustainability, both the EM4800 and EM400 series emphasize energy conservation by promoting efficient energy practices. Users can leverage the collected data to reduce energy costs, enhance equipment performance, and contribute to environmental sustainability efforts.

In summary, Schneider Electric’s EM4800 and EM400 energy meters combine innovative technology with practical features aimed at improving energy management. Their advanced monitoring capabilities, versatile communication options, and focus on power quality make them essential tools for organizations seeking to enhance operational efficiency while reducing their carbon footprint. By investing in these cutting-edge energy solutions, businesses can take significant strides towards sustainable energy management and operational excellence.