CONTROLS, INDICATORS, AND TERMINALS

 

 

 

 

 

 

 

 

INPUT PANEL

OUTPUT PANEL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 1: Input Panel Terminals and Controls

1.SUBSONIC FILTER SELECT SWITCH

The subsonic filter switch allows for a crossover point to be set on the bottom end of the sub- woofer frequency range. Selectable points are 20Hz @ 36dB/oct, 40Hz @ 36dB/oct, or off.

2.LOW-PASS FREQUENCY SELECTOR KNOB (FREQ)

Adjust low-pass crossover frequency between 40 to 200Hz @ 36dB/oct.

3.BASS BOOST CONTROL (BOOST)

Select a boost level between 0dB and +18dB to enhance the bass performance of your sound system.

4.INPUT SENSITIVITY LEVEL CONTROL (SENS)

The input sensitivity level can be varied from 5.0 Volts to 100 mV depending on the output voltage of the source unit (refer to sub-section titled INPUT SENSITIVITY ADJUSTMENT).

5.LINE LEVEL INPUT (RCA)

To be connected to RCA pre-amp outputs from a source unit (i.e., radio, tape deck or CD player).

6.SPEAKER LEVEL INPUT (SPKR LEVEL)

To be connected to speaker outputs from a source unit (i.e., radio, tape deck or CD player) when RCA outputs are not available.

7.LINE LEVEL OUTPUT

This output can be used to connect to another amplifier for system expansion. Note: This line level output is full range.

8.REMOTE SUBWOOFER GAIN INPUT (R S)

To be connected to the optional R S remote subwoofer volume control.

Figure 2: Output Panel Terminals and Indicators

9.POWER AND PROTECT INDICATOR (PWR/PRT) Green light indicates that the amplifier is "ON".

Red light indicates either a high current, short circuit or DC offset is detected at the speaker outputs. The amplifier will revert to normal operation once the problem is rectified.

The Red indicator also lights up at a high operating temperature. Under this condition, the amplifier will automatically shut down. As soon as the temperature falls to a safe level, the amplifier will automatically resume operation.

10.POWER INPUT TERMINAL (B+)

To be connected to the positive terminal of the vehicle’s battery or other constant +12 V source.

11.GROUND INPUT TERMINAL (GND)

To be wired to the vehicle’s chassis for ground.

12.REMOTE TURN-ON INPUT TERMINAL (REM)

To be connected to the remote control wire or power antenna lead of the source unit for remote ON/OFF.

13.FUSE RECEPTACLE

14.DUAL SPEAKER OUTPUT TERMINAL

For connection of a single or dual subwoofer system.

5

Image 3
Contents Mode D’EMPLOI Welcome FeaturesInput Panel CONTROLS, INDICATORS, and TerminalsInstallation LocationMounting Typical Multi-amplifier System BI-AMPLIFICATIONConnect the Amplifier Remote Control Connecting Amplifier Power Wire to the BatteryConnecting Amplifier Ground Wire to the Vehicle Chassis TERMINALS, Lugs and ConnectorsAdjustments Symptom Trouble Shooting Section401DB 801DB SpecificationsCaractéristiques BienvenuPanneau DES Sorties CONTRÕLES, Indicateurs ET ConnecteursMontage EmplacementInstallation traditionnelle Câblage DE L’ALIMENTATION AMPLI/BATTERIE Connexion DU SignalCommande DE Subwoofer Déportée RS EN Option Connexion DES Câbles HAUT-PARLEURSRéglage DE LA Sensibilité RéglagesSélection DE LA Fréquence DE Coupure Réglage DU Filtre Subsonic À 36DB/OCTFrançais Caractéristiques Techniques Important Notice to Consumer Coustic Limited WarrantyU 0 0 0 7 7 0 R e v a 2 / 0