Dual XD1228 owner manual Error Code Cause Action

Page 9

XD1228 OPERATION

 

 

Troubleshooting

 

 

 

Problem

Cause

Action

 

Yellow wire not connected or incorrect voltage

Check connections for proper voltage

Unit will not turn on

Red wire not connected or incorrect voltage

(11~16VDC)

(no power)

Black wire not connected

Check connection to ground

 

Fuse blown

Replace fuse

Unit has power

Speaker wires not connected

Check connections at speakers

One or more speaker wires touching each

Insulate all bare speaker wires from each

(but no sound)

other or touching chassis ground

other and chassis ground

 

 

Yellow or red wire touching chassis ground

Check for pinched wire

Unit blows fuses

Speaker wires touching chassis ground

Check for pinched wire

 

Incorrect fuse rating

Use fuse with correct rating

 

Unit is not mounted correctly

Check mounting sleeve or add a backstrap

Excessive skipping

support

 

 

Physical defect in media (CD, CD-R or CD-RW)

Check media for scratches

 

CD mechanism position out of alignment

Press EJECT for 3 seconds to reset

Unit will not accept

CD mechanism position

 

a disc

CD transit screws still in place

Remove 2 transit screws located on top of

 

the unit.

 

 

 

 

Error Codes

 

 

 

Error Code

Cause

Action

ER-1 appears on the display

Disc error

Press eject or RESET

ER-2 appears on the display

Mechanism error or disc is upside down

Press eject or RESET

ER-3 appears on the display

Servo Error

Press eject or RESET

9

Image 9
Contents XD1228 Preparation Before You StartGetting Started Yellow Wiring DiagramControl Locations Faceplate Removal General OperationTuning Setup MenuLoudness ClockTuner Operation Audio OperationInsert CD Eject CD Track Select CD Player OperationPause Intro Repeat Random CompatibilityCause Action Error Code Cause ActionWhat to do? Limited One Year WarrantyFCC Compliance Fuse 5 amp AGC Tuning range 87.5MHz-107.9MHz