MEMORY CHANNEL TRANSFER

MEMORY \ VFO TRANSFER

After retrieving frequencies and associated data from Memory Recall Mode, you can copy the data to the VFO. This function is useful, for example, when the frequency you want to monitor is near the frequency stored in a Memory Channel.

1Press [MR], then turn the Tuning control or press Mic [UP]/[DWN] to recall the desired Memory Channel.

¥ Alternatively, press [CALL] to select the Call Channel.

2Press [F], [VFO] to copy the Memory Channel data to the VFO.

Note:

On odd-split channels, the above operation copies only the receive frequency to the VFO (not the transmit frequency). To copy the transmit frequency of an odd-split channel, press [REV] before performing the transfer.

You can also transfer the Program Scan memory channels (L0/U0 ~ L2/U2), the Priority Channel (Pr), and the Weather Alert Channel (AL) (K market models only) to the VFO.

Lockout status and Memory Names are not copied from a Memory Channel to the VFO.

CHANNEL \ CHANNEL TRANSFER

You can copy channel information from one Memory Channel to another. This function is useful when storing frequencies and associated data that you temporarily change in Memory Recall Mode.

1Press [MR], then turn the Tuning control or press Mic [UP]/[DWN] to recall the desired Memory Channel.

2Press [F].

3Select the Memory Channel where you would like the

data copied by using the Tuning control or pressing

7

Mic [UP]/[DWN].

 

4Press [MR].

33

Image 40
Contents TM-271A Page Features Thank YOUModels Covered by this Manual Market CodesWhen condensation occurs inside the transceiver One or more of the following statements may be applicableContents MHz Scan IiiMicrophone Control Supplied Accessories Mobile Installation PreparationDC Power Cable Connection Fixed Station Operation Antenna Connection Transceiver 15 a Supplied Accessory 20 a DC Power CableFuse Location Fuse Current Rating Accessory Connections Microphone hanger Microphone hanger screw 3 mm x 10 mmConnecting to a TNC E Market Models only Pin No Pin Name FunctionPress Power briefly to switch the transceiver power on Your First QSOGetting Acquainted Front PanelDisplay MR keyREV key KeyPage Rear Panel MicrophoneCALL/A key VFO/B keyMR/C key PF/D keySwitching the Power ON/OFF Adjusting the VolumeAdjusting the Squelch Operating BasicsWhen you finish speaking, release Mic PTT Selecting a Frequency VFO ModeTransmitting ¥ You must be in VFO mode to make a direct frequency entry Enter ExampleEnter Mic VFO Menu Setup What is a MENU?Menu Access Turn the Tuning control to select your desired MenuMenu Function Selections Default Display Menu Function ListTime-out Timer 10 min Power-on message Characters BeepTuning control lock Call key Varies see 25,35 ReferenceReset selection Data TX speed 1200/ 9600 bpsDisplay brightness Maximum level Automatic display brightnessOperating Through Repeaters Offset Programming FlowProgramming AN Offset To activate Tone, press F, Call Available Tone FrequenciesTone Frequencies Hz Automatic Repeater Offset Call Channel default settingsMarket version only Reverse Function Automatic Simplex Check ASCTone Frequency ID Scan Pressing PTT causes the Ò Ó icon to quit blinkingMemory Channels Number of Memory ChannelsSimplex & Repeater or ODD-SPLIT Memory CHANNEL? Odd-split channels allowParameter Simplex Odd-Split Data listed below can be stored in each Memory ChannelYes DCS code Recalling a Memory Channel Press MR 1sClearing a Memory Channel Press MR to erase the channel dataPress Menu Naming a Memory ChannelPress MR Press F, VFO to copy the Memory Channel data to the VFO Memory Channel TransferMic UP /DWN Channel 0 ~ Call Channel Press Call to recall the Call ChannelWeather Alert K Market Models only WX1 WX2 WX3 WX4 WX5 WX6 WX7Channel Display Page Scan Type Purpose ScanScans the Call Channel Normal Scan Turn the Tuning control or press Mic UP/DWNStoring a Program Scan Frequency Range Press any key other than F or Power to stop Program Scan Press any key other than F or Power to stop MHz ScanPerforming Program Scan Press MR to store the end frequency in the Memory ChannelPress any key other than F or Power to stop Group Scan Memory ScanPress Menu 1s ChannelsPress any key other than F or Power to stop Call Scan Call ScanPriority Scan Press Call 1s to start the Call ScanMemory Channel Lockout Icon disappearsTime-Operated Mode default Carrier-Operated ModeSeek Mode Scan Resume MethodSelective Call Ctcss and DCSCtcss RejectedAvailable Ctcss Tone Frequencies DCS CtcssDCS Code ID Scan DCS CodesDual Tone MULTI-FREQUENCY Dtmf Functions Manual DialingDtmf Monitor Freq. Hz 1209 1336 1477 1633Turn the Tuning control to select a Dtmf code Dtmf TX HoldAutomatic Dialer Press Menu10 4 Press any key other than REV or Menu to exit Press REVRelease Mic PTT Dtmf Lock APO Auto Power OFF Auxiliary FunctionsBeat Shift Meter SquelchBeep Function ÒoffóBusy Channel Lockout Frequency Step SizeDefault step size for each model is as follows Display BacklightMarket Code KHzTune Enable Lock FunctionData Communication Speed Press F 1sMicrophone PF Keys Keypad Models only Programmable FunctionsPOWER-ON Message Narrow Band FM OperationProgrammable VFO Turn the Tuning control to select a characterPress MR to move to the next digit TIME-OUT Timer Storing Power-on Key RX Mode TX ModeMicrophone Control Key MIC LockSpace PS-33/53 SP-50B KMC-30 KMC-32 MC-60AKPG-46 MCP-1A can be downloaded atTroubleshooting MaintenanceResetting the Transceiver Full Reset MethodWith the transceiver power OFF, press F+ Power Press F again to reset the transceiverVFO Reset VFO Reset MethodWith the transceiver power OFF, press VFO+ Power Press VFO again to reset the transceiverTroubleshooting Problem Probable Cause Corrective Action PTTSpecifications GeneralTransmitter Narrow 0.22 ∝V or less