Kenwood TM-271A, TM-271E instruction manual Scan Type Purpose, Scans the Call Channel

Page 46

SCAN

Scan is a useful function for hands-off monitoring of your favorite frequencies. By becoming comfortable with all types of scan, you will increase your operating efficiency.

This transceiver provides the following types of scans.

Scan Type

Purpose

 

Band Scan

Scans the entire band of the

 

frequency you selected

 

 

 

Normal

Program

Scans the specified frequency

ranges stored in Memory

Scan

Scan

Channels L0/U0 ~ L2/U2

 

 

 

 

 

 

MHz Scan

Scans the frequencies within a

 

1 MHz range

 

 

 

 

 

 

All-Channel

Scans all Memory Channels

Memory

Scan

from 0 to 199 (or from 0 to 99)

 

 

 

Scans Memory Channels in

Scan

 

Group Scan

groups of 20 channels (0 ~ 19,

 

 

 

20 ~ 39, 40 ~ 59, etc.)

 

 

 

 

VFO

Scans the Call Channel and

Call

the current VFO frequency

 

Scan

Memory

Scans the Call Channel and

 

Channel

the selected Memory Channel

 

 

 

 

 

Checks the activities on the

Priority Scan

Priority Channel (Pr) every

 

 

3 seconds

 

 

 

Note:

When the CTCSS or DCS function is activated, the transceiver stops at a busy frequency and decodes the CTCSS tone or DCS code. If the tone or code matches, the transceiver unmutes. Otherwise, it resumes scanning.

Press and hold the Mic PF key programmed as MONI {page 59} to pause scan in order to monitor the scanning frequency. Release the key to resume scanning.

Pressing and holding Mic [PTT] causes scan to stop (excluding Priority Scan).

While scanning, you can change the scan frequency direction by turning the Tuning control or using the Mic [UP]/[DWN] keys.

Starting scan switches OFF the Automatic Simplex Check (ASC) {page 26}.

Adjust the Squelch level before using Scan {page 14}. Selecting a Squelch level too low could cause Scan to stop immediately.

8

39

Image 46
Contents TM-271A Page Models Covered by this Manual FeaturesThank YOU Market CodesWhen condensation occurs inside the transceiver One or more of the following statements may be applicableContents MHz Scan IiiMicrophone Control Supplied Accessories Mobile Installation PreparationDC Power Cable Connection Fixed Station Operation Antenna Connection Transceiver 15 a Supplied Accessory 20 a DC Power CableFuse Location Fuse Current Rating Accessory Connections Microphone hanger Microphone hanger screw 3 mm x 10 mmConnecting to a TNC E Market Models only Pin No Pin Name FunctionPress Power briefly to switch the transceiver power on Your First QSOGetting Acquainted Front PanelREV key DisplayMR key KeyPage Rear Panel MicrophoneMR/C key CALL/A keyVFO/B key PF/D keyAdjusting the Squelch Switching the Power ON/OFFAdjusting the Volume Operating BasicsWhen you finish speaking, release Mic PTT Selecting a Frequency VFO ModeTransmitting ¥ You must be in VFO mode to make a direct frequency entry Enter ExampleEnter Mic VFO Menu Access Menu SetupWhat is a MENU? Turn the Tuning control to select your desired MenuMenu Function Selections Default Display Menu Function ListTuning control lock Time-out Timer 10 minPower-on message Characters Beep Call key Varies see 25,35 ReferenceDisplay brightness Maximum level Reset selectionData TX speed 1200/ 9600 bps Automatic display brightnessOperating Through Repeaters Offset Programming FlowProgramming AN Offset To activate Tone, press F, Call Available Tone FrequenciesTone Frequencies Hz Automatic Repeater Offset Call Channel default settingsMarket version only Reverse Function Automatic Simplex Check ASCTone Frequency ID Scan Pressing PTT causes the Ò Ó icon to quit blinkingSimplex & Repeater or ODD-SPLIT Memory CHANNEL? Memory ChannelsNumber of Memory Channels Odd-split channels allowParameter Simplex Odd-Split Data listed below can be stored in each Memory ChannelYes DCS code Recalling a Memory Channel Press MR 1sClearing a Memory Channel Press MR to erase the channel dataPress Menu Naming a Memory ChannelPress MR Press F, VFO to copy the Memory Channel data to the VFO Memory Channel TransferMic UP /DWN Channel 0 ~ Call Channel Press Call to recall the Call ChannelWeather Alert K Market Models only WX1 WX2 WX3 WX4 WX5 WX6 WX7Channel Display Page Scan Type Purpose ScanScans the Call Channel Normal Scan Turn the Tuning control or press Mic UP/DWNStoring a Program Scan Frequency Range Performing Program Scan Press any key other than F or Power to stop Program ScanPress any key other than F or Power to stop MHz Scan Press MR to store the end frequency in the Memory ChannelPress Menu 1s Press any key other than F or Power to stop Group ScanMemory Scan ChannelsPriority Scan Press any key other than F or Power to stop Call ScanCall Scan Press Call 1s to start the Call ScanMemory Channel Lockout Icon disappearsSeek Mode Time-Operated Mode defaultCarrier-Operated Mode Scan Resume MethodCtcss Selective CallCtcss and DCS RejectedAvailable Ctcss Tone Frequencies DCS CtcssDCS Code ID Scan DCS CodesDtmf Monitor Dual Tone MULTI-FREQUENCY Dtmf FunctionsManual Dialing Freq. Hz 1209 1336 1477 1633Automatic Dialer Turn the Tuning control to select a Dtmf codeDtmf TX Hold Press Menu10 4 Press any key other than REV or Menu to exit Press REVRelease Mic PTT Dtmf Lock Beat Shift APO Auto Power OFFAuxiliary Functions Meter SquelchBeep Function ÒoffóBusy Channel Lockout Frequency Step SizeMarket Code Default step size for each model is as followsDisplay Backlight KHzData Communication Speed Tune EnableLock Function Press F 1sMicrophone PF Keys Keypad Models only Programmable FunctionsPOWER-ON Message Narrow Band FM OperationProgrammable VFO Turn the Tuning control to select a characterPress MR to move to the next digit TIME-OUT Timer Storing Power-on Key RX Mode TX ModeMicrophone Control Key MIC LockSpace KPG-46 PS-33/53 SP-50BKMC-30 KMC-32 MC-60A MCP-1A can be downloaded atTroubleshooting MaintenanceWith the transceiver power OFF, press F+ Power Resetting the TransceiverFull Reset Method Press F again to reset the transceiverWith the transceiver power OFF, press VFO+ Power VFO ResetVFO Reset Method Press VFO again to reset the transceiverTroubleshooting Problem Probable Cause Corrective Action PTTSpecifications GeneralTransmitter Narrow 0.22 ∝V or less

TM-271A, TM-271E specifications

The Kenwood TM-271A and TM-271E are robust dual-band transceivers designed for amateur radio enthusiasts looking for reliability, functionality, and ease of use. Both models operate in the VHF and UHF bands, specifically covering 144-148 MHz and 430-450 MHz, respectively. This versatility allows users to communicate across varied frequencies, making them suitable for a wide range of applications, from casual conversations to emergency communications.

One of the standout features of the TM-271A and TM-271E is their compact size, making them an ideal choice for mobile operations. Despite their small footprint, these radios pack a punch with a maximum transmit power of 50 watts in the VHF band and 35 watts in the UHF band. This power output ensures clear and effective communication over long distances, essential for outdoor activities and emergency situations.

The user-friendly interface of the TM-271 models includes a large, backlit LCD display, which provides clear visibility in various lighting conditions. The controls are intuitively arranged, allowing users to navigate functions with ease. Moreover, both models come equipped with an alphanumeric memory, allowing for the storage of up to 200 memories for easy access to frequently used frequencies.

Advanced features such as a built-in CTCSS (Continuous Tone-Coded Squelch System) and DCS (Digital Coded Squelch) enhance communication clarity by minimizing unwanted noise and ensuring that only desired signals are received. The TM-271A and TM-271E also support a wide range of modulation modes, including FM, allowing versatility in communication styles.

In terms of durability and build quality, the Kenwood TM-271 series excels with a rugged design that withstands the rigors of mobile use. The units are also equipped with a front-facing speaker that delivers excellent audio quality, ensuring clear communications even in noisy environments.

Another notable feature is the wideband reception capability, allowing users to listen to signals outside of the amateur bands, making these transceivers more versatile for everyday monitoring of public safety channels and other broadcasts. Furthermore, the inclusion of a built-in diagnostic function aids users in troubleshooting, ensuring that the radio remains in optimal working condition.

In conclusion, the Kenwood TM-271A and TM-271E are outstanding choices for amateur radio operators seeking a powerful, feature-rich, and user-friendly dual-band transceiver. Their combination of advanced technology, compact design, and rugged reliability makes them a popular choice among both novice and experienced operators in the radio community.