Tannoy I15 user manual 100 17.0 35.0 11.0 22.0 14.0 Polarity Checking

Page 4

Should you encounter any problems obtaining Speakon connectors, please contact Neutrik or its distributors directly on the following numbers:-

UK: NEUTRIK MARKETING:

0171 792 8188

USA: NEUTRIK USA INC.:

(201) 901 9488

For a world wide list of distributors, please contact Neutrik directly:-

NEUTRIK AG:

+41 7529666

Cable choice consists mainly of selecting the correct cross sectional area in relation to the cable length and the load impedance. A small cross sectional area would increase the cables series resistance, inducing power loss and response variations (damping factor).

Connectors should be wired with a minimum of 2.5 sq. mm (12 gauge) cable. This will be perfectly satisfactory under normal conditions. In the case of very long cable runs the wire size should exceed this, refer to the following table for guidance:-

CABLE RUN

C.S.A. OF EACH

CABLE

% POWER LOSS

% POWER LOSS

(m)

CONDUCTOR (mm)

RESISTANCE Ω

INTO 8Ω LOAD

INTO 4Ω LOAD

10

2.5

0.14

1.7

3.5

 

4.0

0.09

1.1

2.2

 

6.0

0.06

0.73

1.5

25

2.5

0.35

4.3

8.6

 

4.0

0.22

2.7

5.4

 

6.0

0.14

1.8

3.6

50

2.5

0.69

8.6

17.0

 

4.0

0.43

5.4

11.0

 

6.0

0.29

3.6

7.2

100

2.5

1.38

17.0

35.0

 

4.0

0.86

11.0

22.0

 

6.0

0.58

7.2

14.0

4.Polarity Checking

It is most important to check the polarity of the wiring before the speaker system is used. A simple method of doing this without a pulse based polarity checker for LF units is as follows: Connect two wires to the +ve and -ve terminals of a PP3 battery. Apply the wire which is connected to the +ve terminal of the battery to the speaker cable leg which you believe to be connected to pin 1+ of the speaker connector and likewise the -ve leg of the battery to pin 1-.

If you have wired it correctly the LF drive unit will move forward, indicating the wiring is correct. All that remains now is to connect the +ve speaker lead to the +ve terminal on the amplifier and the -ve lead to the -ve terminal on the amplifier. If however the LF driver moves backwards, the input connections need to be inverted.

If problems are encountered, inspect the cable wiring in the first instance. It should also be noted that different amplifier manufacturers utilise different pin configurations and polarity conventions, if you are using amplifiers from more than one manufacturer, check the polarity at the amplifiers as well as the loudspeakers.

Image 4
Contents I15 Contents Connectors/Cabling IntroductionUnpacking Pin 1+ is Positive Pin 1- is Negative11.0 17.0100 17.0 35.0 11.0 22.0 14.0 Polarity Checking Crossovers Amplification & Power HandlingEqualisation Dimensions Rigging Performance Data Technical Specifications 2nd Harmonic 3rd Harmonic12. i15 Service Parts & Accessories Part Number Description WarrantyWall Mounting Bracket Assembly Instructions Exploded View of Bracket Assembled View of BracketDeclaration of Conformity