Texas Instruments manual ±2. TPA0103 Output Modes, 2.1 S1 Ð Shutdown Jumper

Page 23

Using The TPA0103 EVM With the Plug-N-Play Evaluation Platform

3.3.2.1S1 Ð Shutdown Jumper

To have the module amplifier IC enter the shutdown mode when the module mute control input is activated, set shutdown jumper S1 to ON.

The mute control output pin on the TPA0103 amplifier IC goes high when the mute mode is selected by the output mode jumpers (S2 and S4). Jumper S1 connects the mute output pin to the shutdown control input pin of the IC so that when S1 is ON, the IC is forced into shutdown mode instead of mute mode when the mute mode is selected. When S1 is OFF, a pulldown resistor on the module holds the IC shutdown control input pin low, keeping the IC out of the shutdown mode.

The shutdown mode reduces IC current consumption to approximately 5 μA compared to approximately 1.5 mA in the mute mode. It takes longer, however, to resume normal operation from the shutdown mode (approx. 1 s to 2 s) than it takes to resume normal operation from the mute mode (approx. 100 ms to

500ms).

3.3.2.2S2 and S4 Ð Output Mode Control Jumpers

Two IC amplifier output mode control pins select among three output modes and mute. These pins, Mode A and Mode B, are brought out to module pins and also have jumpers that can hardwire the IC amplifier control inputs high. Table 3±2 shows the relationship between the IC amplifier control inputs and the output modes.

Table 3±2. TPA0103 Output Modes

TERMINAL

3-Channel

Mute

Center Only

L/R Only

 

 

 

 

 

MODE A

L

H

L

H

 

 

 

 

 

MODE B

L

L

H

H

Note: L = logic low, H = logic high

Jumper S2 connects the Mode B output mode control input pin on the amplifier IC directly to VDD regardless of the state of the Mode B module control input. When S2 is OFF, a pulldown resistor on the module holds the Mode B output mode control input pin low. The Mode B control input pin is not directly controlled by anything on the platform Ð the platform socket for that module pin is N/C.

Jumper S4 connects the Mode A output mode control input pin on the amplifier IC directly to VDD regardless of the state of the Mode A module control input, or the input select module control input (HP/L*), or the status of jumper S3 when autosense jumper S5 is set to ON. When S4 is OFF, a pulldown resistor on the module holds the amplifier IC Mode A output mode control input pin low.

Details 3-9

Image 23
Contents Users Guide Important Notice Related Documentation From Texas Instruments PrefacePage Contents Tables FiguresIntroduction Introduction Feature Highlights Description TPA0103 EVM SpecificationsQuick Start ±2. Typical TPA0103 EVM Jumper SettingsAudio Input PrecautionsQuick Start List for Platform ±4. TPA0103 EVM Jumper settingsQuick Start List for Stand-Alone ±5. TPA0103 EVM Stand-Alone Jumper settingsDetails ±1. The TI Plug-N-Play Audio Amplifier Evaluation Platform ±2. TPA0103 EVM TPA0103 Audio Power Amplifier Evaluation Module1 TPA0103 Audio Amplifier IC ±3. TPA0103 EVM Schematic Diagram±1. TPA0103 Output Modes Output ModesInputs and Gain EVM Removal Installing and Removing EVM BoardsEVM Insertion ±5. TPA0103 EVM Jumpers 2 TPA0103 Module Jumper Settings2.1 S1 Ð Shutdown Jumper 2.2 S2 and S4 Ð Output Mode Control Jumpers±2. TPA0103 Output Modes 2.4 S5 Ð Autosense Jumper 2.3 S3 Ð Input Select JumperHeadphone Output Jack Signal RoutingSignal Conditioning Headphone Jack Control Signals Mode ControlMute/Mode Polarity Select JP8 Mute/Mode Select JP6Power Requirements Outputs Inputs and OutputsInputs 1 TPA0103 EVM Connected for Center Channel BTL Output Using The TPA0103 EVM Stand-Alone±10. TPA0103 EVM Connected for Stereo Headphones Output 2 TPA0103 EVM Connected for Stereo Headphones Output±5. TPA0103 EVM Parts List TPA0103 Audio Power Amplifier Evaluation Module Parts List