ViewSonic CD4620, VS11915 Byte Count 00D Bytes order, Length Value1 Value2 Value3 Value4 00D

Page 56
Value[1-4]:

6.2Get-Function Listing

The PC can interrogate the LCD Monitor for specific information. The Get-Function packet format consists of 5 bytes which is similar to the Set-Function packet structure. Note that the “Value” byte is always = 00.

Get-Function description:

 

 

 

 

 

 

 

Length:

 

Total bytes of message = 5 ASCII (35H), excluding “CR”

 

Command:

 

Get-Function command code: One byte ASCII code

 

 

 

Value[1~3]:

 

Always = 000

 

 

 

 

 

Get-Function format from PC to LCD (ASCII)

 

 

 

 

 

Name

 

Length

Command

Value1

Value2

Value3

CR

 

 

Byte Count

 

5

1 Byte

0

0

0

00D

 

 

 

 

 

Bytes order

 

1

2

3

4

5

6

 

 

 

 

Monitor shall response to Get-Function with the following packet format:

LCD Monitor response packet format:

Name

Length

Value1

Value2

Value3

Value4

CR

Byte Count

5

1 Byte

1 Byte

1 Byte

1 Byte

00D

Bytes order

1

2

3

4

5

6

Response packet (to Get-Function):

Length: Total bytes of packet = 5 ASCII excluding “CR”

Exception: Total bytes for On-Hours = 6

Four ASCII codes: Value range is from 0000 ~ 9999

Exception: Value[1-5] for On-Hours

LCD Monitor will send “+” (02Bh), “CR” bytes to PC after receiving a valid command LCD Monitor will send “-” (02Dh), “CR” bytes to PC if the command is not valid

ƒThe following is an example of PC requesting the volume value from the LCD Monitor:

PC send Get-Volume-value packet to Monitor (In ASCII)

Name

Byte Count

Bytes order

Length

Command

Value1

Value2

Value3

CR

5

f

0

0

0

00D

1

2

3

4

5

6

LCD Monitor will send “-” (02Dh), “CR” to PC if command is not recognized. Otherwise the LCD Monitor will respond with the volume value as outlined below:

LCD-Monitor response packet to Get-volume-value (in this example the volume value is 50):

Name

Byte Count

Bytes order

Length

Value1

Value2

Value3

Value4

CR

5

0

0

5

0

00D

1

2

3

4

5

6

A special command “Get-ACK” is used to test the communication link between PC and the LCD Monitor. The LCD Monitor shall response to “Get-ACK” command with a “+” or “-“.

Get-ACK from PC to LCD (ASCII)

Name

Byte Count

Bytes order

Length

Command

Value1

Value2

Value3

CR

5

z

0

0

0

00D

1

2

3

4

5

6

LCD Monitor will send “+” (02Bh); “CR” bytes to PC after receiving the command indicating that the communication link is OK

ViewSonic CD4620

53

Downloaded From TV-Manual.com Manuals

Image 56
Contents ViewSonic Contents Page Compliance Information For U.S.A For CanadaCE Conformity for European Countries Following information is only for EU-member statesImportant Safety Instructions Declaration of RoHS Compliance Product disposal at end of product life Copyright InformationProduct Registration For Your Records Ergonomics Safety PrecautionsRecommended Use Package Contents ViewSonic CD4620 Page Wireless Remote Control Operating Range for the Remote Control Handling the remote controlSetup Procedure Adjust the sound Adjust the screenAdjust the image Recommended AdjustmentVentilation Requirements for enclosure mounting How to Mount and Attach Options to the LCD MonitorUpright position Lay the screen face down To avoid monitor from falling Clamper and Screw is not supplyBefore making connections Wiring DiagramConnections Connecting a Personal Computer Connect the LCD Monitor to a Personal ComputerConnecting with Digital Interface Equipment Connect the LCD Monitor to a Computer with a Digital OutputConnecting a DVD Player with component out Connect the LCD Monitor to a DVD PlayerConnecting to a Stereo Amplifier Connect the LCD Monitor to a Stereo AmplifierPower on and OFF Modes Pressing the Main Power SwitchPressing the power button Using the remote controlPower Indicator Using Power ManagementSelecting a video source To view a video source Picture SizePicture Mode Audio Source SwitchingControl Lock Mode Information OSDScreen Remote Control Control PanelOSD On-Screen-Display Controls Picture Screen PositionAudio Reset AudioBalance TreblePIP Reset PIP Picture in PicturePIP Size PIP AudioConfiguration Power SaveConfiguration Reset Factory ResetOFF Timer OSD Turn OFFInformation OSD OSD H PositionIR Control Advanced OptionGamma Selection Power on Delay Advanced Option ResetTiling Date and TimeRecommendations For long life use of Public DisplayImage Sticking of LCD Panel Remote control numbering function SecondaryControlling the LCD monitor via RS-232C Remote Control ConnectionStand is not supply. Stand sold as an option accessory How to install standsHow to remove the stands Features Troubleshooting 25.0 -165.0 MHz SpecificationsAnalog Input Digital Input Customer Support = FAXLimited Warranty Viewsonic LCD DisplayExclusion of damages Mexico Limited Warranty Viewsonic Display ProductsMerida Introduction Description Protocol 1 with IDProtocol 2 without ID Version control Date Reversion Changes and additionsHardware specification Communication SettingCommand Message Reference Protocol 1, with IDCommand Type CommandSet-Function format Send Command Type=s Reply Command Type=+ orReply Hex Format No Reply CD4620/CD4220 set-function tableEnabled RCU Pass through RCUGet-Function format Send Command Type=g Reply Command Type=r orGet-Function description ReplyHex FormatPC Get-function command to CD4620/CD4220 LCD Monitor Length Command Value1 Value2 Value3 Length Command Value1 Value2 Value3 00DCD4620/CD4220 set command table Set-Function descriptionPass through RCU has no Byte Count 00D Bytes order Length Value1 Value2 Value3 Value4 00DAscii Remote Control Pass-through mode Key Code HEX