Sharp PN-U553 installation manual Specifications

Page 10

Specifications

Model

 

PN-U553

PN-U473

PN-U423

Power requirement

 

AC 100 - 240 V, 1.5 A,

AC 100 - 240 V, 1.5 A,

AC 100 - 240 V, 1.3 A,

 

 

50/60 Hz

50/60 Hz

50/60 Hz

Operating temperature *1

 

41°F to 104°F

32°F to 104°F (0°C to 40°C)

 

 

(5°C to 40°C) *2

 

 

Operating humidity

 

20% to 80% (no condensation)

 

Power consumption

 

130 W

130 W

115 W

Dimensions (excluding protrusions)

inch (mm)

Approx. 49-3/16 (W) x

Approx. 42-5/8 (W) x

Approx. 38-5/16 (W) x

 

 

2-1/4 (D) x 28-3/8 (H)

2-3/16 (D) x 24-11/16

2-1/4 (D) x 22-1/4 (H)

 

 

(1250 x 57 x 721)

(H) (1083 x 55 x 627)

(973 x 57 x 565)

Weight

lbs. (kg)

Approx. 55.2 (25)

Approx. 41.9 (19)

Approx. 35.3 (16)

*1 Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP. In such cases, please check the temperature condition specified by the optional equipments.

*2 Use of the monitors in temperatures below 50°F (10°C) might result in inconsistent image quality that, depending on the viewing angle, might be noticeable along the edges of the screen.

Please note that this is not a malfunction and does not affect monitor operation.

As a part of our policy of continuous improvement, SHARP reserves the right to make design and specification changes for product improvement without prior notice. The performance specification figures indicated are nominal values of production units. There may be some deviations from these values in individual units.

Mounting Precautions (For SHARP dealers and service engineers)

When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people.

Be sure to use a wall-mount bracket designed or designated for mounting the monitor.

This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials such as plaster / thin plastic board / wood before starting installation.

This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor. Install by the most suitable method for the material and the structure.

To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the thickness of the mounting bracket.

Do not use an impact driver.

When moving the monitor, hold the parts marked by below. Do not hold the LCD panel. This may cause product damage, failure, or injury.

After mounting, please carefully ensure the monitor is secure, and not able to come loose from the wall or mount.

Do not use any screw holes other than VESA holes for installation.

E8

Image 10
Contents PN-U553 PN-U473 PN-U423 A. only Important Information ContentsDear Sharp Customer Safety Precautions Safety Precautions Safety InstructionFor the monitor in landscape orientation Mounting PrecautionsFor the monitor in portrait orientation Preparing the Remote Control Unit Supplied ComponentsConnections Turning Power On/Off Status Status of the monitorSpecifications Information Importante Table des matièresCher Client Précautions DE Sécurité Précautions DE Sécurité Suite Mesures DE SécuritéPour le moniteur dans une direction verticale Précautions Pour LE MontagePour le moniteur dans une direction horizontale ’ENPLOIPréparation de la télécommande Composants fournisBornes d’entrée audio2 ConnexionsComponent COMPOSANT, Video Vidéo Mise sous tension et hors tension État État du moniteurCaractéristiques 721 H 627 H 565 H Poids EnvironEstimado Cliente DE Sharp Información ImportanteEE.UU. Sólo Precauciones DE Seguridad Precauciones DE Seguridad Continuación Instrucciones DE SeguridadPara el monitor en orientación vertical Precauciones DE MontajePara el monitor en orientación horizontal InstruccionesComponentes suministrados Preparación de la Unidad de control remotoConexiones Encendido/apagado Estado Estado del monitorEspecificaciones Page 0NY47M184309A1