JBL GTO1201.1, GTO755.6, GTO601.1, GTO301.1, GTO75.4 Troubleshooting, Symptom Likely Cause Solution

Page 7

INSTALLATION AND SETUP

Figure 13. Installing neon tubes in a JBL GTO amplifier.

TROUBLESHOOTING

SYMPTOM

LIKELY CAUSE

SOLUTION

No audio

No voltage at BATT+

Check voltages at

(POWER LED

or REM terminals,

amplifier terminals

is off)

or bad or no ground

with VOM

 

connection

 

No audio

DC voltage on

Amplifier may need

(PROTECT LED

amplifier output

service; see enclosed

flashes every

 

warranty card for

4 seconds)

 

service information

No audio

Amplifier is

Make sure amplifier

(PROTECT

overheated

cooling is not blocked

LED is on)

 

at mounting location;

 

 

verify speaker system

 

 

impedance is within

 

 

specified limits (see

 

 

“Specifications” on

 

 

the next page)

No audio

Voltage less than 9V on

Check vehicle

(PROTECT

BATT+ connection

charging system for

and POWER

 

defective voltage

LEDs flash)

 

regulator

To Neon

Power

Supply

To Neon

Power

Supply

SYMPTOM

LIKELY CAUSE

SOLUTION

No audio

Voltage more than 16V

Check vehicle

(PROTECT

or less than 8.5V on

charging system for

LED is on)

BATT+ connection

defective voltage

 

regulator

 

Distorted audio

Input sensitivity is

Check INPUT

 

not set properly, or

LEVEL setting; or

 

amplifier or source

check speaker wires

 

unit is defective

for shorts or grounds

Distorted audio

Short circuit in

Remove speaker leads

and PROTECT

speaker or wire

one at a time to locate

LED flashes

 

shorted speaker or

 

 

wire, then repair

Music lacks

Speakers are not

Check speaker

“punch”

connected properly

connections for

 

 

proper polarity

7

Image 7
Contents Thank YOU Installation Warnings and Tips InstallationChoosing a Location and Mounting the Amplifier Applications GTO75.2 Applications GTO301.1, GTO601.1 and GTO1201.1Figures 6 through Applications GTO75.4Applications GTO755.6 Input Mode switchInstalling Neon Tubes Optional Installation and SetupSetting Crossovers Setting Input SensitivitySymptom Likely Cause Solution TroubleshootingGTO75.4 SpecificationsGTO301.1 GTO601.1 GTO1201.1 GTO75.2