Jensen 1304, 1150, 1302, 420, 840 Troubleshooting, Problem Possible Cause Corrective Action

Page 13

Troubleshooting

Problem

Possible Cause

Corrective Action

Amplifier does not

No power to +12V

Check fuse(s)

turn on

terminal

 

 

No power to REM

Check head unit fuse(s) and

 

terminal

wiring

 

Blown main fuse at

Replace fuse and identify

 

battery

cause of failure

 

Blown fuse at amplifier

Replace fuse and identify

 

 

cause of failure

 

Faulty ground

Re-ground main power

 

 

ground to bare metal

 

 

chassis

Volume control too

Input level control

Re-adjust the input level

sensitive

adjusted too high

(refer to page 8)

Distorted sound

Input level control

Re-adjust the input level

 

adjusted too high

(refer to page 8)

Blows fuse(s) at amp

Power wires connected

Reconnect power wires

 

backwards

properly

 

Internal problem with

Take unit for service

 

amp

 

Engine noise /

Ground loop(s)

Use good quality shielded

Alternator whine

 

RCA cables

 

Faulty ground at amp

Re-ground amp to clean

 

 

bare metal chassis

 

Faulty ground at head

Re-ground head unit to

 

unit

clean bare metal chassis

 

Inductive coupling

Re-route RCA and/or

 

 

speaker wires away from

 

 

factory harnesses

 

Input level on amp set

Re-adjust input level (refer

 

too high

to page 8)

Thermal protection

Amplifier driving 2 ohm

If the amplifier “thermals”

activated

load for long durations

frequently while driving

 

 

subwoofers, install fan to

 

 

keep amp cool.

13

PowerPlus Amplifiers

Short circuit

Blown speakers

Check all speakers

protection activated

 

 

Speaker wire(s) shorting

Check for faulty wiring

 

to ground

 

 

Defective crossover

Faulty passive crossover

Low impedance

Amp connected to

Check speaker connections

protection activated

improper load

 

 

Amp will not drive a 1

Verify that speakers are

 

ohm mono load, 2 ohm

connected properly

 

minimum in mono

 

 

configuration

 

 

Speakers defective/

Check speakers

 

blown

 

 

Faulty passive

Check crossovers

 

crossovers

 

Poor bass response

Speakers out of phase

Check speaker polarity;

 

 

reverse the connection to

 

 

one speaker only if two

 

 

subwoofers are connected

 

 

to the amplifier.

NOTE: If the protection light is activated with no speakers connected to the amplifier, and all the power connections are correct, this would indicate an internal problem with the amplifier.

Image 13
Contents PowerPlus Amplifiers Introduction Warranty ServiceBefore You Begin Specifications Features and SpecificationsPower Output Installation Assistance Supplies and Tools Needed InstallationRouting Wires Disconnect BatteryPower Terminal +12V/B+ Power WiringCharging System Remote Terminal REMGround Terminal GND Replacement Fuse Requirements FusePowerPlus 900/1150 Speaker WiringPowerPlus 420/1302 Four Speakers PowerPlus 840/1304Two Speakers and Bridged Subwoofer Two SubwoofersPowerPlus 420/900/1150/1302 Input WiringConnecting Additional Amplifiers Indicators and Controls Reconnect Battery TestingTest Power Wiring Remote Input Level ControlProblem Possible Cause Corrective Action TroubleshootingRMS Power Output @ 1% THD+N, 14.4VDC CEA Power Output