Clark Synthesis TA0.1 owner manual Specifications, Amplifier Section

Page 22

SPECIFICATIONS

General

 

 

Power Supply

100 – 240 VAC, 50/60 Hz, Auto

• Standby Current

(110 VAC / 220 VAC)

0.12 A / 0.11 A

• Max Current (110 VAC / 220 VAC)

2.4 A / 1.1 A

Total Amplifier Efficiency

70%

• Dimensions (Amplifier) (W x H x D)

5.125 in x 2.75 in x 8.875 in (130.2 mm x 69.9 mm x 225.4 mm)

• Dimensions (Remote Control Interface) (W x H x D)

5 in x 2.125 in x 2 in (127 mm x 54 mm x 50 mm)

• Remote Control Wire Length

Approx. 4 ft.

Weight

4.0 lbs. (1.814 kg)

Fuse

T3AL 250V

Input Section

 

 

Input Impedance

16 kΩ

Input Sensitivity

(1 W, Input switch set to Low)

30 mV

Input Sensitivity

(1 W, Input switch set to High)

100 mV

Input Sensitivity

(150 W, Input switch set to Low)

360 mV

Input Sensitivity

(150 W, Input switch set to High)

1 V

Loop Through Amplification

x 1

Auto-On

Switch Selectable

Crossover Section

 

 

Crossover Frequency Selection

40 Hz – 400 Hz

• Crossover Frequency Selection (+ 0 dB, -3 dB)

35 Hz – 420 Hz

Amplifier Section

 

• Output Power....................................................................................................................150 Watts RMS into 4 Ohms

• Total Harmonic Distortion (at 1 Watt into 4Ω).......................................................................................................0.15%

• Total Harmonic Distortion (at 150 Watts into 4Ω).................................................................................................0.08%

• Frequency Response..............................................................................................................................5 Hz to 36 kHz

• Frequency Response (+0 dB, -3 dB)....................................................................................................28 Hz to 36 kHz

5.125 in (130.2 mm)

8.625 in (219.1 mm)

 

7.375 in (187.3 mm)

 

2.75 in

 

(69.9 mm)

Amplifier- Input/Output Panel View

 

 

 

 

Amplifier- Side View

 

 

 

 

 

 

 

 

 

 

 

 

.125 in

.875 in

 

 

 

 

 

(3.17 mm)

 

(22.2 mm)

 

 

 

 

 

 

 

 

 

 

 

22

TA0.1 Amplifier

 

 

 

 

 

www.clarksynthesis.com

Image 22
Contents TA0.1 Amplifier with Wired Remote Company Overview Warranty United States Warranty and Return PolicySafety Instructions Product Introduction Overview of the AmplifierPackage Contents Unpacking Your AmplifierProduct Overview Product Overview Remote Control Overview Gain Volume ControlConnector Audio INPUT/OUTPUT Connectors Input/Output Panel OverviewRemote Control Wire Connector Setting UP Your Amplifier Quick Setup InstructionsPlacing/Mounting the Amplifier Initial Settings Prior to Making Connections Connecting the Audio Source Home TheaterLF Center RF LFE/SUB CH1 CH2 CH3 Connecting the Transducer to the Amplifier Using the Powered Loop-Through To Run Multiple Transducers Operating Your Amplifier Balancing the Transducer with the SubwooferPhoto #4 Photo #5 Specifications Amplifier SectionTroubleshooting Symptom Troubleshooting Question RemedyGlossary of Terms Term DefinitionGlossary of Terms Symbols IndexIndex Phone Fax Email info@clarksynthesis.com