Problem

Amplifier fuse keeps blowing.

Solution

Incorrect wiring or short circuit. Review Installation and check all wiring connections.

Problem

Whining or ticking noise in the audio with engine on.

Solution

Amplifier is picking up alternator noise or radiated noise. Turn down input gain; move audio cables away from power wires. Check power and ground connections on amplifier; install an in-line noise filter on source unit’s power wire; check alternator and/or voltage regulator; test for weak battery or add water to battery.

PRODUCT SPECS

Frequency Response

20Hz ~ 20kHz

Signal Noise Ratio

>95db

THD

.05% all channels driven

Input Sensitivity Low Level

250mV ~ 2.5V

Input Sensitivity Speaker Level

500mV ~ 5V

Max. Power Output

640W (160 x4)

Cont. Power Output

320W (80W x4) @.05% THD

2-Ohm Stereo Output

115W x 4 @ .5% THD

Bridged Power

230W x 2 @ .5% THD

Dimensions

2 1/8” H x 8 1/4” W x 12” L

Current Consumption @ Max

46A @ 640 Watts

Power Output

 

12

Image 14
Contents APX480M manual.qxd 3/12/2004 107 PM Introduction About the Manual and WarrantyTable of Contents Description Input Connections and Audio CONTROLsHigh-pass/Low-pass Filter Controls Operation/Installation Manual Connections for Power and SpeakersWiring Precautions InstallationMounting Precautions Wiring and Applications Channel Full-Range Stereo SystemChannel Stereo System Channel High-Pass, 2-Channel Low-Pass Channel Stereo System with Low-Pass Bridged Mono Channel Channel High Power System Satellite or Subwoofer Mixed-Mode System On Rear Full-Range Speakers On Front Setting the Bass Boost Setting the GainSetting the Crossover Troubleshooting Final System CheckProduct Specs THDClarion Limited Warranty APX480M manual.qxd 3/12/2004 107 PM