Crate Amplifiers TG10R technical specifications Remove COVER. no USER-SERVICEABLE Parts Inside

Page 2

TG10R Guitar Amplifier

Congratulations and thank you for choosing the Crate TG10R Guitar Amplifier. This rugged amplifier provides you with serious clean and distorted sounds and fea- tures two bands of equalization, reverb, CD Input jacks, and a jack for headphones.

In order to get the most out of your new amplifier, we strongly urge you to read this user’s guide before you begin playing.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

 

 

 

PRECAUCION

 

 

 

ATTENTION

 

 

RISK OF ELECTRIC SHOCK

 

 

 

RIESGO DE CORRIENTAZO

 

 

 

RISQUE D'ELECTROCUTION

 

 

DO NOT OPEN

 

 

 

NO ABRA

 

 

 

NE PAS OUVRIR

 

 

 

 

 

 

 

 

 

 

WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC

 

PRECAUCION: PARA REDUCIR EL RIESGO DE INCENDIOS O DESCARGAS

 

ATTENTION: PROTÉGEZ CET APPAREIL DE LA PLUIE ET DE L'HUMIDITÉ

SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOIS-

 

ELECTRICAS, NO PERMITA QUE ESTE APARATO QUEDE EXPUESTO A LA

 

AFIN D'ÉVITER TOUT RISQUE D'INCENDIE OU D'ÉLECTROCUTION. POUR

TURE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT

 

LLUVIA O LA HUMEDAD. PARA DISMINUOIR EL RIESGO DE CORRIENTAZO.

 

REDUIRE D'ELECTROCUTION NE PAS ENLEVER LE COUVERCLE. AUCUNE

REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE.

 

NO ABRA LA CUBIERTA. NO HAY PIEZAS ADENTRO QUE EL USARIO PUEDO

 

PIECE INTERNE N'EST REPRABLE PAR L'UTILISATEUR. POUR TOUTE

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

 

REPARAR DEJE TODO MANTENIMIENTO A LOS TECHNICOS CALIFICADOS.

 

REPARATION, S'ADRESSER A UN TECHNICIEN QUALIFIE.

IMPORTANT SAFETY INSTRUCTIONS

READ, FOLLOW, HEED, AND KEEP ALL INSTRUCTIONS AND WARNINGS.

DO NOT OPERATE NEAR ANY HEAT SOURCE AND DO NOT BLOCK ANY VENTILATION OPENINGS ON THIS APPARATUS. FOR PROPER OPERATION, THIS UNIT REQUIRES 3” (75mm) OF WELL VENTILATED SPACE AROUND HEATSINKS AND OTHER AIR FLOW PROVISIONS IN THE CABINET.

DO NOT USE THIS APPARATUS NEAR SPLASHING, FALLING, SPRAYING, OR STANDING LIQUIDS.

CLEAN ONLY WITH LINT-FREE DAMP CLOTH AND DO NOT USE CLEANING AGENTS.

ONLY CONNECT POWER CORD TO A POLARIZED, SAFETY GROUNDED OUTLET WIRED TO CURRENT ELECTRICAL CODES AND COMPATIBLE WITH VOLTAGE, POWER, AND FREQUENCY REQUIREMENTS STATED ON THE REAR PANEL OF THE APPARATUS.

PROTECT THE POWER CORD FROM DAMAGE DUE TO BEING WALKED ON, PINCHED, OR STRAINED.

UNPLUG THE APPARATUS DURING LIGHTNING STORMS OR WHEN UNUSED FOR LONG PERIODS OF TIME.

ONLY USE ATTACHMENTS, ACCESSORIES, STANDS, OR BRACKETS SPECIFIED BY THE MANUFACTURER FOR SAFE OPERATION AND TO AVOID INJURY.

WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK OR FIRE, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE.

SERVICE MUST BE PERFORMED BY QUALIFIED PERSONNEL.

OUR AMPLIFIERS ARE CAPABLE OF PRODUCING HIGH SOUND PRESSURE LEVELS. CONTINUED EXPOSURE TO HIGH SOUND PRESSURE LEVELS CAN CAUSE PERMANENT HEARING IMPAIRMENT OR LOSS. USER CAUTION IS ADVISED AND EAR PRO- TECTION IS RECOMMENDED IF UNIT IS OPERATED AT HIGH VOLUME.

EXPLANATION OF GRAPHICAL SYMBOLS:

"DANGEROUS VOLTAGE"

"IT IS NECESSARY FOR THE USER TO REFER TO THE INSTRUCTION MANUAL"

EXPLICACION DE SIMBOLOS GRAFICOS:

= “VOLTAJE PELIGROSO”

= “ES NECESARIO QUE EL USUARIO SE REFIERA AL MANUAL DE INSTRUCCIONES.”

EXPLICATION DES SYMBÔLES GRAPHIQUES:

"DANGER HAUTE TENSION"

"REFERREZ-VOUS AU MANUAL D'UTILISATION"

 

TG10R Guitar Amplifier

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

1:INPUT: Connect your guitar to this jack by means of a shielded instrument cable.

2:OD LEVEL: Use this control to adjust the volume and intensity of the Overdrive channel. This control is only active when the OD/Clean switch (#3) is depressed.

3.OD/CLEAN: Use this switch to select the OD channel (switch depressed) or the Clean channel (switch in the out position). The OD channel gives you sounds rang- ing from crunchy rhythm to screaming leads, while the Clean channel gives you sounds from sparkling clean to slightly crunchy.

4:CLEAN LEVEL: Use this control to adjust the volume of the Clean channel. This control is only active when the OD/Clean switch (#3) is in the out position.

5:HIGH: Use this control to adjust the output level of the high frequencies. Rotating this control counter clockwise reduces the high frequency output; rotating it clock- wise increases it.

6:LOW: Use this control to adjust the output level of the low frequencies. Rotating this control counter clockwise reduces the low frequency output; rotating it clock- wise increases it.

7.REV LEVEL: Use this control to adjust the amount of reverberation added to the signal. With the control in the fully counter clockwise position the signal is “dry” (no reverb). As you rotate the control clockwise the amount of reverb increases.

8.CD INPUT: Use these RCA jacks to connect an external source (such as a CD player, tape player or rhythm machine) to the amplifier. The signal at these jacks is summed into a mono signal which is sent to the internal power amp circuit. Use the external source’s output level control to adjust the signal for the proper mix with your instrument.

9:HEADPHONES: Use this jack to connect a pair of stereo headphones for private listening. The external speaker is disconnected when headphones are in use.

10:POWER LED: This LED illuminates when power is applied to the amplifier.

11:POWER SWITCH: Use this switch to turn the amplifier on (top of the switch depressed) and off (bottom of the switch depressed).

12:AC LINE IN: (Rear panel, not shown) The grounded power cord should only be plugged into a grounded power outlet that meets all applicable electrical codes and is compatible with the voltage, power, and frequency requirements stated on the rear panel. Do not attempt to defeat the safety ground connection.

Image 2
Contents TG10R Explication DES Symbôles Graphiques Remove COVER. no USER-SERVICEABLE Parts InsideRefer Servicing to Qualified Service Personnel