Inside Installation

Control Panel Installation

STEP 1: Run control cable from roof mount to control panel. Do not connect to control panel at this time.

STEP 2: Connect power cable to a fused 12VDC source. It is recommended that the power source is separate from other appliances, to avoid possible electrical interference. Do not connect wire to control panel at this time. Note: Orange wire supplied for optional "Antenna Up" warning. DO NOT connect it to a 12VDC power source.

STEP 3: Run coax cable from roof mount to power source for antenna head preamplifier. Power source may be a powered 12VDC video switch or wall plate power supply. Connect a second coax cable from power source to television.

STEP 4: Control panel can be mounted directly to surface providing surface has sufficient space behind panel for wiring. Should you be limited to space behind panel or choose not to have wires concealed behind control panel, you can use the surface mount box.

STEP 5: After prepping area to mount control panel, test fitting to make sure it fits in location correctly, and connect control cable and power wires to panel. Then secure panel to it's location.

Refer to Operations Manual for instructions to raise, lower, and rotate antenna.

Control Panel

.625

4.485

4.564

NOTE: SHOWN WITHOUT

SURFACE MOUNT BOX.

.875

3.280

3.674

POWER CABLE CONNECTION

CONTROL CABLE CONNECTION

5

Image 5
Contents Winegard Motorized Sensar Antenna Tools needed for installation Tools Needed/SpecificationsPre-Installation Requirements Roof Installation Control Panel Installation Inside InstallationReturn Authorization Policy Warranty