Bosch Appliances TC9217MM-W instruction manual Mm dia. holes to a minimum depth of 2.5

Page 6

WARNING

When installing BOSCH wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica- tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or cavity.

Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

 

Make sure that the wall will safely support four times the combined load of the equipment and all attached hard-

 

ware and components.

 

 

 

 

For Concrete Walls use wall arm (W), making sure

1

 

 

 

that it is level, as a template to mark holes. Drill 1/

 

concrete

 

4" (6 mm) dia. holes to a minimum depth of 2.5" (64

 

 

wall

 

mm). Insert concrete anchors in holes flush with

 

 

 

 

wall as shown (right). Place wall arm (W) over

 

 

 

 

anchors and secure with #14 x 2.5" (6 mm x 65

 

 

ACC 204

 

mm) wood screws (V). Tighten all fasteners.

 

 

 

 

 

 

 

WARNING

Drill hole(s) and insert anchor(s)

 

 

2

 

 

Tighten wood screws so that wall plate is firmly

wall arm

 

 

 

 

 

 

 

attached, but do not overtighten. Overtightening can

 

 

 

 

damage the screws, greatly reducing their holding

 

 

 

 

power.

 

 

ACC 204

Never tighten in excess of 80 in • lb (9 N.M.).

 

 

 

Make sure that mounting screws are anchored into the

Place arm over anchor(s) and secure with screw(s)

 

center of the studs. The use of an "edge to edge" stud

3

 

 

 

finder is highly recommended.

 

 

 

 

 

 

 

WARNING

 

 

 

Concrete anchors are not intended for attachment to

 

 

 

 

concrete wall covered with a layer of plaster, drywall,

Tighten all fasteners

 

 

 

or other finishing material. If mounting to concrete wall

 

 

 

 

 

 

 

covered with plaster/drywall is unavoidable, plaster/

 

 

 

 

drywall (up to 5/8" thick) must be counterbored as

 

 

 

 

shown below. If plaster/drywall is thicker than 5/8",

 

 

 

 

custom fasteners must be supplied by installer.

 

 

 

 

CUTAWAY VIEW

 

ACC 204

 

 

 

 

 

 

INCORRECT

wall

concrete

arm

 

 

plaster/

 

dry wall

 

CORRECT

wall

concrete

arm

 

 

plaster/

 

dry wall

CONCRETE

WALL

W

V

6 of 12

ISSUED: 06-25-99 SHEET #: 039-9003-8 02-08-05

Image 6
Contents TC9217MM-W, TC9220MM-W, TC9227MM-W Monitor Mount Compatibility Chart Installation and Assembly Bosch Monitor Wall Mounts T I O N a L Wood Stud Wall Mm dia. holes to a minimum depth of 2.5 Detail Bottom View Parts List Wall Issued 06-25-99 Sheet # 039-9003-8