Desa 4E769B operating instructions Accessories

Page 13

Dayton Operating Instructions and Parts Manual

4E769B

Model 4E769B

Troubleshooting Chart (Continued)

Symptom

Possible Cause(s)

Corrective Action

 

 

 

Heater shuts down while running

1. High surrounding air temperature

 

causing thermal limit device to shut

 

down heater

 

2. Restricted air flow

 

3. Damaged fan

4. Excessive dust or debris in surround-

ing area

 

 

Accessories

 

 

 

 

Description

Part No.

 

 

 

 

10' Rubber Hose with Brass Fitting

LPA1020

U.L. listed.

 

 

15' Rubber Hose with Brass Fitting

LPA1030

U.L. listed.

 

 

Propane Gas Regulator

LPA2110

U.L. listed.

 

 

Hose/Regulator Assembly

LPA3090

U.L. listed.

 

 

Fuel Gas Connector

LPA4020

Connects regulator to all standard

 

 

propane tanks. U.L. and A.G.A. listed.

 

 

Tank Stabilizer

LPA5000

1.This can happen when running heater in temperatures above 85°F.

Run heater in cooler temperatures

2.Check heater inlet and outlet. Remove any obstructions

3.Replace fan. See Fan, page 8

Use only in areas free of high dust

content.

4. Clean heater. See Maintenance, page 7

®

13

Version B - For Reduction

G016.J

Image 13
Contents Unpacking DescriptionDayton Propane Construction Heater General Safety InformationElectrical Specifications SpecificationsProduct Identification Propane Supply Theory of OperationVentilation InstallationOperation To Start HeaterStorage MaintenanceTo Stop Heater To Restart HeaterElectrical System Service ProceduresIgnitor For Replacement Parts, call Replacement Parts List Troubleshooting Chart Accessories 4E769B 4E769B Limited Warranty