TECHNICAL SUPPORT (FAQ) (cont.)

CLOCK (pixel frequency) controls the number of pixels scanned by one horizontal sweep. If the frequency is not correct, the screen shows vertical stripes and the picture has not correct width.

FOCUS adjusts the phase of the pixel clock signal. With a wrong phase adjustment the picture has horizontal disturbances in light picture.

For FOCUS and CLOCK adjustment use “dot-pattern” or win 95/98 shut-down mode pattern.

ERROR MESSAGE & POSSIBLE SOLUTION

CABLE NOT CONNECTED :

1.Check that the signal-cable is properly connected , If the connector is loose, tighten the connector’s screws.

2.Check the signal-cable’s connection pins for damage.

INPUT NOT SUPPORT :

Your computer has been set to unsuitable display mode ,set the computer to display mode given in the following table.

UNSUPPORTED MODE TRY DIFFERENT VIDEO CARD SETTING:

Your computer resolution is out of VESA-SPEC

18

Image 20
Contents PL1500 Internet Support Talk to a Customer Service Representative Page Table of Contents For Your Safety FCC Class B Radio Frequency Interference StatementPrecautions General Notes Special Notes on LCD MonitorsBefore YOU Operate the Monitor FeaturesChecking the Contents of the Package Installation Instructions Power SourceInstallation Instructions Cable ConnectionsAdjusting the Viewing Angle External Controls Operating InstructionsGeneral Instructions Power Button /Power Indicator Operating INSTRUCTIONScontOSD Lock Function HOW to Adjust a Setting Operating InstructionsAdjusting the Picture Main Sub Menu Description IconMain Sub Description Menu Icon Plug and Play Technical Support FAQ BlueTechnical Support FAQ Error Message & Possible Solution Cable not ConnectedUnsupported Mode TRY Different Video Card Setting Input not SupportSpecifications AppendixAppendix Preset Display Modes Connector PIN Assignment TDXQ41G5000935 1B