Elite Screens VMAX2 manual Elite Screens Infrared Remote Control Code, Type X Vmax Only

Page 1

4/23/2007

ELITE SCREENS INFRARED REMOTE CONTROL CODE

1.Spectrum, VMAX2 (Plus), Home2(3) and Tension2(3) Series The wave shape of sending :

And the difference between “0” and “1”

1

3a

a a

0

3a

“a” is the wave period of 16 X 38K.

Up: 1111 0000 0001

Stop:1111 0000 0010

Down:1111 0000 0100

2. VMAX (Plus), SilverMax, CineTension Series

2.1: Type U ( VMAX Only)

Frequency455Khz

UP 010010000

STOP 010001000

DOWN : 010000100

2.2Type G ( VMAX, SilverMAX and CineTension) MCU Code(IR + RF control code protocol) Remote

Head code+8 digital address code+8 digital operation code Head Code = 48 counts (Count Clock=32767time/sec) Digital "1"=24 counts (Counter clock = 32767tim/sec) Digital "0"=12Counts (Counter clock = 32767tim/sec)

Low level voltage in between each digi. =24 (Counter clock=32767time/sec)

8 digits address code:

1~5digits mapping code to circuit board , high 3 digits and then 0 8 digits operation code

UP 0xDD

STOP 0xCC

DOWN 0xEE

2.3Type X ( VMAX Only)

(1) IR Controller is using IC # 2272 and 22262 to send and receive. Frequency: 38KHZ

UP 1000

STOP 0100 DOWN : 0010

3.Home Series

Up 0xB1 0x4E 0x90 0x6F

Stop 0xB1 0x4E 0x8A 0x75

Down 0xB1 0x4E 0xCA 0x35

Elite Screens Inc.

Main: (562) 483-8198 / Fax: (562) 483-8498 / www.elitescreens .com / eliteinfo@elitescreens.com

Image 1
Contents Vmax Plus, SilverMax, CineTension Series Type U Vmax Only Elite Screens Infrared Remote Control CodeType X Vmax Only Home Series