Jacuzzi 300 instruction manual Setting of limiter

Page 5

WARNING: This is a guide to help you set the Rotational Limit Stop. This is only a guide and should be verified by following the instructions on setting the rotational limit stop given in this installation and instruction sheet.

 

 

 

 

 

MIX TEMPERATURE-VS-POSITION OF ROTATIONAL LIMIT STOP

 

 

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE MIX TEMPERATURE (°F) WITH VARYING INLET TEMPERATURES

 

 

 

Setting of limiter

Cold Hot

 

Cold Hot

 

Cold Hot

 

Cold Hot

 

Cold Hot

 

Cold Hot

 

Cold Hot

 

Cold

Hot

 

 

 

 

 

 

 

 

 

 

 

50°F 120°F

 

70°F 120°F

 

50°F 140°F

 

70°F 140°F

 

50°F 160°F

 

70°F 160°F

 

40°F 180°F

 

85°F

180°F

 

1st Position

SHU

T OFF ZONE: NO FLOW APPROXIMATELY 0-20 DEGREES OF HANDLE ROTAT

ION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2nd Position

50

 

 

70

 

50

 

70

 

70

 

70

 

40

 

 

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3rd Position

61

 

 

79

 

67

 

83

 

74

 

89

 

70

 

 

101

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4th Position

68

 

 

83

 

75

 

90

 

84

 

97

 

84

 

 

110

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5th Position

74

 

 

87

 

85

 

96

 

91

 

104

 

95

 

 

117

 

 

6th Position

79

 

 

90

 

91

 

101

 

99

 

110

 

103

 

 

125

 

 

7th Position

82

 

 

93

 

97

 

104

 

104

 

115

 

109

 

 

130

 

 

8th Position

85

 

 

95

 

104

 

107

 

108

 

118

 

115

 

 

135

 

 

(Factory Set)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9th Position

89

 

 

100

 

117

 

111

 

115

 

124

 

124

 

 

141

 

 

10th Position

98

 

 

105

 

134

 

121

 

128

 

136

 

140

 

 

153

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11th Position

111

 

 

115

 

138

 

133

 

149

 

151

 

165

 

 

172

 

Setting of limiter

The first position of the Rotational Limit Stop (the Limiter) is that position that restricts the rotation of the stem the most and is at the maximum counterclockwise setting. According to industry standards, the maximum allowable temperature of the water exiting from the valve is 120°F. This temperature may vary in your local area. The Rota- tional Limit Stop may need to be readjusted if the inlet water temperature changes. For instance, during the winter, the cold water temperature is colder than it is during the summer which could result in varying outlet temperatures. Typical temperature for a comfortable bath or shower is between 90°-110°F.

©1995 Jacuzzi Whirlpool Bath G570000 D 12/06

Page 5

Image 5