Sony MDS-S50 specifications Using the Continuously Recorded Disc, Checks Prior to Repairs

Page 28

MDS-JE470

5-5. USING THE CONTINUOUSLY RECORDED DISC

*This disc is used in focus bias adjustment and error rate check. The following describes how to create a continuous recording disc.

1.Insert a disc (blank disc) commercially available.

2.Rotate the lAMS L knob and display “CREC1 MODE”.

3.Press the YES button again to display “CREC1 MID”. Display “CREC (0300)” and start to recording.

4.Complete recording within 5 minutes.

5.Press the MENU/NO button and stop recording .

6.Press the AEJECT button and remove the disc.

The above has been how to create a continuous recorded data for the focus bias adjustment and error rate check.

Note :

• Be careful not to apply vibration during continuous recording.

5-6. CHECKS PRIOR TO REPAIRS

These checks are performed before replacing parts according to “approximate specifications” to determine the faulty locations. For details, refer to “Checks Prior to Parts Replacement and Adjust- ments” (See page 9).

5-6-1. Temperature Compensation Offset Check

When performing adjustments, set the internal temperature and room temperature to 22 to 28ºC.

Checks cannot be performed properly if performed after some time from power ON due to the rise in the temperature of the IC and diode, etc. So, perform the checks again after waiting some time.

Checking Procedure:

1.Rotate the lAMS L knob to display “TEMP CHECK”. (C12)

2.Press the YES button.

3.“T=@@(##) [OK]” should be displayed. If “T=@@ (##) [NG]” is displayed, it means that the results are bad.

(@@ indicates the current value set, and ## indicates the value written in the non-volatile memory.)

5-6-2. Laser Power Check

Before checking, check the Iop value of the optical pick-up. (Refer to 5-8. Recording and Displaying Iop Information.)

Connection :

Laser power meter

Optical pick-up objective lens

Digital volt meter

BD board

CN105 pin 1 (I+3V)

CN105 pin 2 (IOP)

Checking Procedure:

1.Set the laser power meter on the objective lens of the optical pick-up. (When it cannot be set properly, press the m button or M button to move the optical pick-up.)

Connect the digital volt meter to CN105 pin 1 (I+3V) and CN105 pin 2 (IOP).

2.Then, rotate the lAMS L knob and display “LDPWR CHECK”.

3. Press the YES button once and display “LD 0.9 mW $ ”. Check that the reading of the laser power meter become the specified value.

4.Press the YES button once more and display “ LD 7.0 mW $

”. Check that the reading the laser power meter and digital volt meter satisfy the specified value.

Specified Value :

Laser power meter reading : LD 0.9mW : 0.85-0.91mW (260B) 0.90-0.96mW (260E)

LD 7.0mW : 6.80-7.20mW (260B) 7.00-7.50mW (260E)

Digital voltmeter reading : Optical pick-up displayed value ± 10%

(Optical pick-up label)

KMS260B

(For details of the method for checking

20101

this value, refer to “5-8. Recording and

H0576

Displaying Iop Information”.)

R

Iop = 57.6 mA in this case

Iop (mA) = Digital voltmeter reading (mV)/1 ()

5.Press the MENU/NO button and display “LDPWR CHECK” and stop the laser emission.

(The MENU/NO button is effective at all times to stop the laser emission.)

Note 1: After step 4, each time the YES button is pressed, the display will be switched between “LD 0.7 mW $ ”,

“LD 6.2 mW $ ”, and “LD Wp $ ”. Nothing needs to be performed here.

5-6-3. Iop Compare

The current Iop value at laser power 7 mw output and reference Iop value (set at shipment) written in the nonvolatile memory are compared, and the rate of increase/decrease will be displayed in percentage.

Note: Perform this function with the optical pick-up set at room temperature.

Procedure

1.Rotate the lAMS L knob to display “Iop Compare”.

2.Press the YES button and start measurements.

3.When measurements complete, the display changes to “±xx%yy”.

xx is the percentage of increase/decrease, and OK or NG is displayed at yy to indicate whether the percentage of increase/ decrease is within the allowable range.

4.Press the MENU/NO button to end.

28

Image 28
Contents Specifications 873-891-11SELF-DIAGNOSIS Function MDS-JE470Three- or five Digit code Cause/Remedy Message Items of Error History Mode Items and Contents Table of Contents DisassemblyDiagrams Exploded ViewsMDS-JE470 Section Service Notes Safety CHECK-OUTFlexible Circuit Board Repairing LeakageJIG for Checking BD Board Waveform IOPRecord Precedure KSN-260E Optical PICK-UP Block Type DiscriminationForced Reset Checks Prior to Parts Replacement and AdjustmentsMain Board Component Side Retry Cause Display Mode Bit BinaryHigher Bits Lower Bits Hexa Details Bit When BinaryHexadecimal Binary MDS-JE470 Section General Button DescriptionsMDS-JE470 Section Disassembly Disassembly FlowFront Panel Section Main Board PT BOARD, VOL-SEL Board SP modelMechanism Deck Section MDM-7A Over Light Head HR901, BD BoardHolder Assy Loading Motor Assy M103Sled Motor Assy M102, Slider Optical PICK-UPSpindle Moter Assy M101 MDS-JE470 Section Test Mode Precautions for USE of Test ModeSetting the Test Mode Exiting the Test ModeSelecting the Test Mode DisplayOperating the Continuous Playback Mode MENU/NOTest Mode Displays Mode displayError rate display Functions of Other ButtonsWhen Memory NG is Displayed Meanings of Other DisplaysAutomatic SELF-DIAGNOSIS Function InformationParts Replacement and Adjustment MDS-JE470 Section Electrical AdjustmentsCheck before replacement Adjustment flow Precautions for USE of Optical PICK- UP KMS-260B/260E Precautions for Checking Laser Diode EmissionPrecautions for Adjustments Using the Continuously Recorded Disc Checks Prior to RepairsAuto Check Other ChecksTraverse Check Traverse WaveformPlay Check MO Error Rate Check CD Error Rate CheckFocus Bias Check Self-Recording/playback CheckTemperature Compensation Offset Adjutment Initial Setting of Adjustment ValueLaser Power Adjustment Traverse Adjustment Iop NV SaveFocus Bias Adjustment Error Rate Check Auto Gain Control Output Level AdjustmentCD Auto Gain Control Output Level Adjustment MO Auto Gain Control Output Level AdjustmentAdjusting Points and Connecting Points MDS-JE470 Section Diagrams Circuit Boards LocationFor schematic diagrams For printed wiring boardsBD Board Main BoardIC171 Block Diagrams BD SectionIC190 IC360 2/2 Main SectionIC1 2/2 SemiconductorOVER SemiconductorBoard Board Main Display Board Schematic Diagram Main /2 See page 51 for IC Block DiagramsIC1 KEY-SW Board Schematic Diagram Display Section Indicator TubePT Board 230VSchematic Diagram Power Section IC Block Diagrams IC101 CXA2523AR BD BoardIC500 AK4524 Main Board IC101 CXA2523AR RF Amplifier BD Board IC PIN Function DescriptionPin No Pin Name Description Pin No Pin Name Desription SqsyMvci Abbreviation EFM Eight to Fourteen Modulation IC1 M30803MG-107FP System Control Main Board ADA. Latch STB Section Exploded Views Chassis SectionFL750 Mechanism MDM-7A M101 Electrical Parts List CoilsMetal Chip Display MDS-JE470 KEY-SW MainMDS-JE470 Main CN2TC7WHU04FUTE12R MDS-JE470 Main VOL-SEL Screw +KTP 2X6 TYPE2 NON-SLITMDS-JE470 MDS-JE470 Revision History

MDS-S50 specifications

The Sony MDS-S50 is a pinnacle of MiniDisc technology, offering audiophiles a compact and reliable way to enjoy high-quality audio. Launched in the early 2000s, it epitomizes the innovation that Sony was known for during this period, combining functionality with sleek design.

One of the primary features of the MDS-S50 is its ability to record in SP (Standard Play) mode, which delivers high-resolution audio at 64 kbps, and LP (Long Play) mode for extended recording times. This flexibility makes it suitable for various listening preferences, whether for critical listening or casual playback during everyday activities. The device harnesses the precision of digital audio encoding, ensuring minimal loss of sound quality.

The MDS-S50 stands out with its direct digital recording capabilities. By connecting to external audio sources via optical or coaxial digital inputs, users can preserve the integrity of the original sound. This feature is particularly appealing for those who want to capture live recordings or transfer vinyl records and CDs to the MiniDisc format without degradation.

The inclusion of a user-friendly interface, with an intuitive remote control and well-organized menu systems, enhances the experience for users. The display panel gives clear information on track titles, remaining recording time, and other essential details, allowing for seamless navigation through complex playlists or recording options.

Another notable technology in the MDS-S50 is the ATRAC (Adaptive Transform Acoustic Coding) compression algorithm, developed by Sony. This proprietary encoding format optimizes sound quality while significantly reducing file sizes. The result is a perfect balance between audio fidelity and efficient storage, which was a major advantage during the era of burgeoning digital music.

Furthermore, the MDS-S50 boasts a durable build quality, designed to withstand transport and everyday use. Its compact size, combined with lightweight materials, allows users to take it on the go while not compromising on audio quality.

Ultimately, the Sony MDS-S50 remains a beloved device among music enthusiasts. With its combination of high-quality recording capabilities, advanced digital encoding technology, and user-friendly features, it represents a unique chapter in the evolution of portable audio. Whether used as a standalone player or part of a larger audio setup, it delivers a level of performance that still resonates with those who appreciate the art of music.