Ecom Instruments Ex-Handy 05 Application, Safety information, Faults and damage

Page 4

1. Application

The Ex-Handy 05 is an intrinsically safe, splash water-, dust- and impact-resi- stant mobile phone for industrial application in areas with an increased risk of explosion in zones 1 and 2, in accordance with directive 1999/92/EC (ATEX 137).

2. Safety information

This operating manual contains information and safety regulations which are to be observed without fail for safe operation in the described conditions. Non-ob- servance of this information and these instructions can have serious conse- quences or may violate regulations. Please read these operating instructions carefully before starting to use the phone!

In case of any doubt (in the form of translation or printing errors) the German language operating instructions shall apply.

3. Faults and damage

If there is any reason to suspect that the safety of the unit has been impaired, it must be withdrawn from use and removed immediately from the Ex-area. Measures must be undertaken to prevent it from being restarted accidentally.

The safety of the unit may be compromised, if, for example:

-there is visible damage to the housing.

-the unit has been subjected to excessive loads.

-the unit has been improperly stored.

-the unit has been damaged in transit.

-unit markings or inscriptions are illegible.

-malfunctions occur.

-permitted limit values have been exceeded.

4. Safety regulations

Use of the explosion-proof mobile phone Ex-Handy 05 assumes that the operator complies with conventional safety regulations and has read the certificate in order to eliminate faulty operation of the unit.

The following points are to be observed:

-The device may not be opened inside the Ex-area.

-Only the original battery module Ex-AMH 05 (Li-ion 3.7V/850 mAh) may be used!

-The battery module may not be changed inside the Ex-area!

-The battery module may only be charged outside the Ex-area and only then using the following appropriate chargers: charger LGH 05, car charger ALH 05, Car-Kit CKH 05 or USB data cable PCH 05.

-When changing the battery the battery compartment and the circulating seal are to be examined for any contamination and cleaned, if necessary, with a brush or by using blasts of compressed air.

39

Image 4
Contents Ex-Handy Page Table of Contents Safety information Faults and damageSafety regulations ApplicationEx-Data SpecificationsFunctional description / Operating instructions Page Page Function is abandoned Hold down In initial screen Silent modeFunctions of the sub-menus Gprs Page Dial the number of your correspondent. Press First callEnd of the conversation press It could also affect the quality of your communications Phonebook Using the phonebook Page Key Page Page Page Page Page Key. If you are logging onto the GSM or Gprs network, Page You can deactivate the sound by pressing the key Vibrate Page Call waiting Operator-dependent service ALS Confidentiality Shortcuts Battery Changing the batteryPage Charging the battery Repair Cleaning, maintenance and storageDisposal Warranty and liability EC Declaration of ConformityEC-Type Examination Certificate Page Copyright 2007 ecom instruments GmbH