MAINTENANCE AND TROUBLE-SHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays).

PROBLEM: The power does not turn on

a. Make sure that the power cord is plugged into a surge suppressor, and that the surge suppressor is plugged into a properly grounded outlet (see page 7). Use only a single-outlet surge suppressor that is UL 1449 listed as a transient voltage surge suppressor (TVSS). The surge suppressor must have a UL suppressed voltage rating of 400 volts or less and a minimum surge dissipation of 450 joules. The surge suppressor must be electrically rated for 120 volts AC and 15 amps. Important: The treadmill is not compatible with GFCI- equipped outlets.

b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.

c. Check the circuit breaker located on the treadmill frame near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

PROBLEM: The power turns off during use

c

Tripped

Reset

a. Check the circuit breaker located on the treadmill frame near the power cord (see the drawing above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in.

c. Remove the key from the console. Reinsert the key fully into the console.

d. If the treadmill still will not run, please call our Customer Service Department, toll-free.

PROBLEM: The displays of the console do not function properly

a. Check the batteries in the console. If the batteries need to be replaced, see ÒBATTERY INSTALLATIONÓ on page 8. Most problems are the result of drained batteries.

b. Remove the screws from the hood, and carefully remove the hood. Locate the Reed Switch (76) and the Magnet (93) on the left side of the Pulley (77). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that there is a gap of about 1/8Ó between the Magnet and the Reed Switch. If nec- essary, loosen the Screw (17) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading.

44

1/8Ó

50

 

 

 

 

 

45

33

 

 

Top

 

 

View

 

 

12

Image 12
Contents QUESTIONS? Model No. WLTL49200 Serial NoCustomer HOT Line Table of Contents Important PrecautionsPage Before YOU Begin Right SideBack Assembly Screws Operation and Adjustment HOW to Plug in the Power CordPerformant Lubetm Walking Belt Diagram of the Console Battery InstallationSTEP-BY-STEP Console Operation CALORIES/FAT CALORIES/PULSEHOW to Fold and Move the Treadmill HOW to USE the Hand WeightsHOW to Fold the Treadmill for Storage HOW to Move the Treadmill HOW to Lower the Treadmill for USEMaintenance and TROUBLE-SHOOTING Problem The power turns off during useTop Problem The walking belt slows when walked on 2ÓÐ3ÓConditioning Guidelines Exercise IntensityWorkout Guidelines Exercise Frequency Suggested StretchesPart LISTÑModel No. WLTL49200 Qty DescriptionExploded DRAWINGÑModel No. WLTL49200 Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT