Newcon Optik NVS 4 operation manual

Page 12

Note: If zeroing range is different, the value of click changes proportionally, for example:

-at range 50 m - 1.5 cm;

-at range 200 m - 6.0 cm.

Example: On the Fig.3 the mean point of impact is located above the aiming point by 15 cm and at the left by 20 cm. To shift the mean point of impact to target centre one should turn the vertical adjustment screw by 15/3 = 5 clicks down and the horizontal adjustment screw by 20/3 = 7 clicks to the right. Make the batch of check shooting.

Grouping of scope aimed shooting should not be worse than without the scope. No adjustment should be made after zeroing. When shooting a range exceeding 100 m you should keep zeroing but choose another aiming point corresponding to the distance to the target.

Figure 3.

9

Image 12
Contents NVS Important Information Table of contents Some of the typical activities where NVS 4 will be useful FeaturesOverview Precautions Delivery SET Specifications NVS4Design Page Operation Instructions Page Page Maintenance Storage Troubleshooting Device does not workImage is degraded and blurred Unit flashesCondensation accumulates on the parts Visibility decreases and / or disappearsReticle is absent or weak Warranty What This Warranty Does Not CoverCustomer Support Acceptance Certificate Night Vision Device NVSNewcon Optik