Honeywell op10 manual Wire Gage Specifications, Distance Gage Conductor

Page 2

TABLE 1: WIRE GAGE SPECIFICATIONS

Distance

Gage

5 Conductor

6 Conductor

200 ft. (61m)

22

Alpha 1295C

Alpha 1296C

300 ft. (91m)

20

Alpha 58126

Alpha 58126

500 ft. (153 m)

18

Alpha 58136

Alpha 58136

 

 

 

 

Note: Recommended cable is only a guideline, use any manufacturer that meets the gage and shield specifications.

HOW TO TEST AND OPERATE THE READER

The reader should be tested after wiring it to a power supply and the host. Do this by performing the following steps:

1.Power up the reader. The LED and beeper will activate three times. This indicates that the reader is working properly.

2.Present the appropriate type of ID card to the reader. (See Table 2 for the correct card type based on the reader model.) The LED will momentarily flash green and a short beep will be emitted. This indicates that the card was read properly by OmniProx.

3.After the card data is processed by the host, the host can then turn the LED green or yellow. Refer to the host description of the LED operation if the reader LED is controlled by the host.

Table 2: Model Number vs. Feature Matrix

Model

UL Listing

Card

Output

Read

Number

Part #

Type

Format

Range

 

 

 

 

(Max.)*

OP10-FW

AY-K10

HID

Wiegand

3”

 

 

 

 

 

OP20-FW

AY-J10

HID

Wiegand

4”

OP30-FW

AY-L10

HID

Wiegand

5”

 

 

 

 

 

OP40-FW

AY-H10

HID

Wiegand

4”

 

 

 

 

 

OP45-FW

AY-M10

HID

Wiegand

4”

 

 

 

 

 

OP90-FW

AY-Q10

HID

Wiegand

1.5”

 

 

 

 

 

*Measured using HID Corp. Prox Card II (P/N 1326LSSMV) or equivalent and the corresponding OmniProx reader powered at 12 volts. Range also depends on electrical environment and/or proximity to metal.

SPECIFICATIONS

Electrical Characteristics:

Power Supply Type:

Linear type Recommended

Operating Voltage Range:

5.0– 16 VDC (Operational down to 4.25 VDC)

Maximum input current: OP10, OP20, OP90

Standby: 35 mA

Read: 50 mA OP30, OP40, OP45

Standby: 35 mA

Read: 100 mA

Tamper Output

Open collector, active low, max.sink current is 16 mA

Maximum Cable Distance to Host: 500 ft. (150 meters)

Card Read Distance:

See Table 2

Regulatory Approvals:

USA: UL 294 Listed & FCC Part 15 B (Model OP90 is not yet UL listed)

Europe: CE Listed

Operating Temperature Range:

-25° F to 145° F (-31°C to 63°C)

Operating Humidity:

0 to 95% (non condensing) Suitable for outdoor use

Dimensions:

OP10:

3.15” (80mm) L x 1.58” (40mm) W x 0.50” (12.8mm) D

OP20:

4.73” (120mm) L x 1.65” (42mm) W x 0.55” (14mm) D

OP30:

5.71” (145mm) L x 1.69” (43mm) W x 0.79” (20mm) D

OP40:

4.33” (110mm) L x 2.96” (75mm) W x 0.59” (15mm) D

OP45:

3.5” (89mm) L x 3.5” (89mm) W x 0.59” (15mm) D

OP90:

4.72” (120mm) L x 3” (76mm) W x 1” (27mm) D

For additional information on the Wiegand™ Protocol, see “Access Control Standard – Wiegand Card Reader Interface SIA AC-01 (1996.10)” which can be purchased from SIA (see www.siaonline.org)

OmniProx models with HID compatibility are capable of reading genuine HID cards under the terms of a license agreement between HID Corp. and the ADEMCO Group.

-2-

Image 2
Contents To surface mount the reader, perform the following HOW to Mount the ReaderHOW to Connect the Reader to the Host Specifications Wire Gage SpecificationsHOW to Test and Operate the Reader Distance Gage ConductorFederal Communications Commission FCC Part 15 Statement CE CertificationAdemco Limited Warranty Eileen Way, Syosset, New York