Omega Speaker Systems Advance 300 manual Manual and Auto Calibration Instructions

Page 2

Manual and Auto Calibration Instructions

For Models: Advance 205 T20 T30 T40 2.0T 3.0T 4.0T 5.0T Free Spirit 200 Free Spirit 300 Free Spirit 400 1.1T 2.1T 3.1T 4.1T 5.1T

F1

10%

 

 

 

 

10mph

 

10 %

 

 

 

 

 

10

mph

9 %

 

 

 

 

 

9 mph

8 %

 

 

 

 

 

8 mph

7 %

 

 

 

 

 

7 mph

6 %

 

Distance / Laps

 

Time

 

6 mph

 

 

 

 

 

5 %

 

 

 

 

 

5 mph

 

4 %

Manual

Intervals

Rolling

Weight Loss

Hill Run

4 mph

 

 

 

 

 

 

 

3 %

Hill Climb

Race

THR Zone

Custom 1

Custom 2

3 mph

 

 

 

 

 

 

 

2 %

 

 

 

 

 

2 mph

 

1 %

START

 

SELECT

 

STOP

1 mph

 

 

 

INCLINE

 

SPEED

 

 

 

F2

TRANSFORMER

F3

 

 

SPEED CUBE

Step One Entering the Engineering Mode

1Turn the treadmill power to ON.

2Place the safety key in position on the console.

3Simultaneously press and hold (for about five seconds) the following buttons:

For Models 3.0T 4.0T 5.0T Free Spirit 200, 300, 400: The “10%” and “10mph” buttons.(F1)

All other Models: The incline “+” (s) and speed “-” (t) buttons.(F1 & F2)

4The console should beep three times and ENG0 (EN90) should be displayed. This indicates you are in the engineering menu.

Note: if ENG0 (EN90) is not displayed, but ENG (EN9) is displayed with another number at the end, you are still in the engineering menu. Use the “+” (s) or “-” (t) buttons to navigate to the correct menu. See following instructions.

Step Two Manual Calibration

1Press the speed “+” (s) or “-” (t) button until ENG1 (EN91) is displayed.

2Press and hold the “Start” button for about three seconds to select.

For Models 4.1T 5.1T: Press and hold the “Select” button for about three seconds to select.

WARNING

Do NOT stand on the running belt when calibrating. Use the guide rails instead.

3Press the “Start” button to begin manual calibration. The Running belt should begin moving.

4The readout in the speed window will indicate the start speed of the unit. This should be 0.5mph (+ or - .05). If the speed is not within the proper start range, adjust the speed cube (F3) until the speed window (F2) readout is correct.(See note below)

Note: The speed cube is located on the Motor Control Board. It is blue with a small yellow screw. (F3) When adjusting the speed cube, turn the screw right to increase the speed and left to decrease the speed. Use small increments as the speed cube is sensitive and will respond to each change. DO NOT PUSH DOWN HARD ON THE SCREW.

5Once the speed readout is at the proper setting, press and hold the “Stop” button for about three seconds to return to the engineering menu. Proceed to the following instructions to Auto Calibrate the unit.

Step Three Auto Calibration

After following the steps above you will have one step left to complete the calibration process.

Note: If you are not in the engineering menu, follow steps 1-4 from Entering the Engineering Mode.

1Press the speed “+” (s) or “-“ (t) buttons until ENG2 (EN92) is displayed.

2Press and hold the “Start” button for about three seconds to select.

For Models 4.1T 5.1T: Press and hold the “Select” button for about three seconds to select.

3Press the “Start” button to begin.

The running belt will begin moving and will automatically begin the auto-calibration sequence to properly set and store the speed values. Upon successful calibration there will be four beeps and it will automatically exit the Engineering Mode and will return to the original screen. The whole process will typically take about two minutes.

Manual and Auto Cal _rev1.5 08/17/07 JHP

Image 2
Contents For Models Omega II Advance 200 in the Time window Entering Diagnostics ModeManual Calibration Instructions Step Two Manual Calibration Step One Entering the Engineering ModeManual and Auto Calibration Instructions Step Three Auto CalibrationEntering the Engineering Mode Auto Calibration Instructions