TROUBLE-SHOOTING

Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at 1-800-999-3756, Monday through Friday, 6 a.m. until 6 p.m. Mountain Time (excluding holidays).

PROBLEM: The power does not turn on

SOLUTION: a. Make sure that the power cord is plugged into a surge protector, and that the surge protector is plugged into a properly grounded outlet. (See HOW TO PLUG IN THE POWER CORD on page 7.) Use only a UL-listed surge protector, rated at 15 amps, with a 14-gauge cord of five feet or less in length

b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.

c. Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.

d. Check the on/off switch located on the treadmill near the power cord. The switch must be in the on position.

PROBLEM: The power turns off during use

c

 

Tripped

Reset

d

On

 

 

Position

SOLUTION: a. Check the circuit breaker located on the treadmill near the power cord (see c. above). If the circuit breaker has tripped, wait for five minutes and then press the switch back in.

b. Make sure that the power cord is plugged in.

c. Remove the key from the console. Reinsert the key fully into the console.

d. Make sure that the on/off switch is in the on position (see d. above).

e. If the treadmill still will not run, please call our Customer Service Department, toll-free.

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only an appropriate surge protector (see a. near the top of this page).

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts counterclockwise 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 2 to 3 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, in- sert the key, and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

2ÓÐ3Ó

Rear Roller

Bolts

c. If the walking belt still slows when walked on, please call our Customer Service Department, toll- free.

12

Image 12
Contents QUESTIONS? Model No. IMTL22991 Serial NoCustomer HOT Line Table of Contents Important PrecautionsPage Before YOU Begin Assembly Your own adjustable wrench not includedHOW to USE the Heart Rate Monitor HOW to PUT on the Heart Rate MonitorHeart Rate Monitor Care and Maintenance Heart Rate Monitor TROUBLE-SHOOTINGOperation and Adjustment HOW to Plug in the Power CordPerformant Lubetm Walking Belt Console Diagram Features of the ConsoleSTEP-BY-STEP Console Operation HOW to USE the Manual Mode DISTANCE/LAPSHOW to USE Workout Programs HOW to USE the Information Mode Press the Start button to start the programFollow your progress with the four displays Whenkey. the program is completed, removeTROUBLE-SHOOTING Problem The power turns off during useProblem The walking belt slows when walked on Top ViewProblem The heart rate monitor does not function properly Conditioning Guidelines Exercise IntensityWorkout Guidelines Part LISTÑModel No. IMTL22991 Qty DescriptionExploded DRAWINGÑModel No. IMTL22991 Ordering Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT