TROUBLE-SHOOTING
Most treadmill problems can be solved by following the steps below. Find the symptom that applies, and follow the steps listed. If further assistance is needed, please call our Customer Service Department toll- free at
PROBLEM: The power does not turn on
SOLUTION: a. Make sure that the power cord is plugged into a surge protector, and that the surge protector is plugged into a properly grounded outlet. (See HOW TO PLUG IN THE POWER CORD on page 8.) Use only a
b. After the power cord has been plugged in, make sure that the key is fully inserted into the console.
c. Check the circuit breaker located on the treadmill near the power cord. If the switch protrudes as shown, the circuit breaker has tripped. To reset the circuit breaker, wait for five minutes and then press the switch back in.
d. Check the on/off switch located on the treadmill near the power cord. The switch must be in the on position.
PROBLEM: The power turns off during use
c |
|
Tripped | Reset |
d |
|
On |
|
Position |
|
SOLUTION: a. Check the circuit breaker located on the treadmill frame near the power cord (see c. above). If the
circuit breaker has tripped, wait for five minutes and then press the switch back in.
b. Make sure that the power cord is plugged in.
c. Remove the key from the console. Reinsert the key fully into the console.
d. Make sure that the on/off switch is in the on position.
e. If the treadmill still will not run, please call our Customer Service Department,
PROBLEM: The displays of the console do not function properly
SOLUTION: a. Remove the key from the console and unplug the power cord. Carefully tip the treadmill down as shown in drawing a. Remove the Screws (39, 83) from the hood. Raise the Uprights (69) and carefully remove the hood.
b. Locate the Reed Switch (10) and the Magnet (7) on the left side of the Pulley (8). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8Ó. If necessary, loosen the Screw
(80)and move the Reed Switch slightly. Retighten the Screw.
a |
| |
| 39 | |
69 | 83 | |
| ||
b |
| |
1/8Ó | 8 | |
80 | ||
| ||
10 | 7 | |
Top |
| |
View |
|
26