Spirit XT285 owner manual Grounding Instructions, Important Electrical Instructions

Page 5

IMPORTANT ELECTRICAL INSTRUCTIONS

WARNING!

NEVER use a ground fault circuit interrupt (GFCI) wall outlet with this treadmill. As with any appliance with a large motor, the GFCI will trip often. Route the power cord away from any moving part of the treadmill including the elevation mechanism and transport wheels.

NEVER remove any cover without first disconnecting AC power. If voltage varies by ten percent (10%) or more, the performance of your treadmill may be affected. Such conditions are not covered under your warranty. If you suspect the voltage is low, contact your local power company or a licensed electrician for proper testing.

NEVER expose this treadmilll to rain or moisture. This product is NOT designed for use outdoors, near a pool or spa, or in any other high humidity environment. The operating temperature specification is 40 to 120 degrees Fahrenheit, and humidity is 95% non-condensing (no water drops forming on surfaces).

Circuit Breakers: Some circuit breakers used in homes are not rated for high inrush currents that can occur when a treadmill is first turned on or even during use. If your treadmill is tripping the house circuit breaker (even though it is the proper current rating) but the circuit breaker on the treadmill itself does not trip, you will need to replace the home breaker with a high inrush type. This is not a warranty defect. This is a condition we as a manufacture have no ability to control. This part is available through most electrical supply stores. Examples: Grainger part # 1D237, or available online at www.squared.com part # QO120HM.

GROUNDING INSTRUCTIONS

This product must be grounded. If the treadmilll should malfunction or breakdown, grounding provides a path of least resistance for electric current, reducing the risk of electric shock. This product is equipped with a cord having an equipment-grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product if it will not fit the outlet; have a proper outlet installed by a qualified electrician.

This product is for use on a nominal 110-volt circuit, and has a grounding plug that looks like the plug illustrated below. A temporary adapter that looks like the adapter illustrated below may be used to connect this plug to a 2-pole receptacle as shown below if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet, (shown below) can be installed by a qualified electrician. The green colored rigid ear-lug, or the like, extending from the adapter, must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw.

3

XT285 Treadmill

Image 5
Contents XT285 Treadmill Table of Contents Product Registration Important Safety Instructions Important Electrical Instructions Grounding InstructionsImportant Operation Instructions Safety Tether CordXT285 Assembly Instructions 1UPRIGHT Tube Assembly XT285 Treadmill 2CONSOLE Assembly 3PLASTIC Parts Assembly Transport Folding InstructionsHandrail Adjustments FeaturesQuick Speed & Incline Buttons ConsoleGetting Started Operation of Your ConsoleQUICK-START/MANUAL Operation PAUSE/STOP/RESET FeatureIncline Feature Handrail Buttons Disable Switch Pulse Grip FeatureMile Track Calorie DisplaySelect a Preset Program Programmable FeaturesHill Preset ProgramsStrength Heart Rate Programs Rate of Perceived Exertion Using Heart Rate Transmitter Heart Rate Program Operation General Cleaning General MaintenanceBelt Adjustments BELT/DECKSetting TREAD-BELT Tracking Treadbelt Tracking AdjustmentBELT/DECK Lubrication Procedure Service Checklist Diagnosis Guide Calibration Procedure MANUFACTURER’S Limited Warranty