Healthrider HRTL08012 manual Problem The walking belt slows when walked on, Top

Page 24

Locate the Reed Switch (18) and the Magnet (101) on the left side of the Pulley (78). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8”. If necessary, loosen the 3/4” Screw (24) and move the Reed Switch slightly. Retighten the Screw. Re-attach the hood, and run the treadmill for a few minutes to check for a correct speed reading.

PROBLEM: The walking belt slows when walked on

1/8”

78

24

 

18

101

Top

 

View

 

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 8.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, in- sert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

b

3”–4”

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, call our Customer Service Department toll-free.

PROBLEM: The walking belt is off-center or slips when walked on

SOLUTION: a. If the walking belt is off-center, first remove the key and UNPLUG THE POWER CORD. If the walking belt has shifted to the left, use the allen wrench to turn the left rear roller bolt clockwise 1/2 of a turn; if the walking belt has shifted to the right, turn the bolt counterclockwise 1/2 of a turn. Be careful not to overtighten the walking belt. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b. If the walking belt slips when walked on, first remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller bolts clockwise, 1/4 of a turn. When the walking belt is correctly tight- ened, you should be able to lift each side of the walk- ing belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and carefully walk on the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

a

b

PROBLEM: The incline of the treadmill does not change correctly or does not change when iFIT.com CDs and videos are played

SOLUTION: a. With the key inserted in the console, press one of the Incline buttons. While the incline is changing, remove the key. After a few seconds, re-insert the key. The treadmill will automati- cally rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline.

24

Image 24
Contents QUESTIONS? Model No. HRTL08012 Serial NoCustomer HOT Line Table of Contents Important Precautions Page Before YOU Begin Left Side Right SideAssembly Driver and rubber malletScrews as tight as possible Operation and Adjustment HOW to Plug in the Power CordPerformant Lubetm Walking Belt Console Diagram Features of the ConsoleHOW to Turn on the Power HOW to USE the Manual ModeSelect the manual mode Insert the key fully into the consoleMoving your hands. When your Distance/LapsMeasure your heart rate, if desired Whenkey. you are finished exercising, removeHOW to USE Personal Trainer Programs Select one of the personal trainer programsHOW to USE Heart Rate Programs Follow your progress with the displaysPut on the chest pulse sensor Select a heart rate programEnter your age HOW to Connect Your Portable Stereo HOW to Connect Your Home Stereo HOW to Connect Your ComputerHOW to Connect Your VCR Audio Adapter CableInsert the key into the console PressVCR. the Play button on your CD player orWhenkey. the program is completed, remove HOW to USE Programs Directly from OUR WEB Site When the program has ended, remove the keyFollow the on-line instructions to start the program Information MODE/DEMO Mode Rate display is blankOptional Chest Pulse Sensor HOW to Fold and Move the Treadmill HOW to Fold the Treadmill for StorageHOW to Move the Treadmill HOW to Lower the Treadmill for USE TROUBLE-SHOOTING Problem The power turns off during useProblem The walking belt slows when walked on TopConditioning Guidelines Exercise IntensityWorkout Guidelines Exercise FrequencySuggested Stretches Page Remove this Exploded Drawing and Part List from the Manual R0102A Key Qty DescriptionHRTL08012 HOW to Order Replacement Parts Limited WarrantyIcon Health & FITNESS, INC., 1500 S W., LOGAN, UT