Sears 831.2974 owner manual Symptomthe Walkingbeltslowswhenwalkedon

Page 10

4. SYMPTOM:THE WALKINGBELTSLOWSWHENWALKEDON

Apply silicone lubricant to the walking platform before use. Reapply lubricant after every 10

hours of use, and whenever a decrease in performance is noticed. (Uni.Sport silicone spray is

recommended.) CAUTION: UNPLUG THE POWER CORD WHEN APPLYING LUBRICANT.

(See OPERATION AND ADJUSTMENT in this manual for application instructions.)

b.If an extension cord is needed, use only a 14-gaugegeneral-purpose cord of five feet or less in length.

C.

If the walking belt is overtightened, treadmill performance

I

 

 

may decrease and the walking belt may be permanently

 

 

damaged. Remove the safety key and UNPLUG THE

 

 

POWER CORD. Using the allen wrench, turn both rear

 

 

roller adjustment bolts counterclockwise, 1/4 of a turn.

 

 

When the walking belt is properly tightened, you should

 

 

be able to lift each side of the walking belt 3-4 inches off

 

 

the walking platform. The center of the walking belt

 

 

should just touch the walking platform. Be careful to

 

 

keep the walking belt centered. Plug in the power cord,

 

 

insert the safety key and run the treadmill for a few min-

Rear Roller Adjustment Bolts

 

utes. Repeat until the walking belt is properly tightened.

 

 

5.SYMPTOM: THE WALKING BELT IS OFF-CENTER OR SLIPS WHEN WALKED ON

a. If the walking belt has shifted to the left, first remove the

a,

safety key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjustment bolt

clockwise, and the right bolt counterclockwise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the safety key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

b, If the walking belt has shifted to the right, first remove the safety key and UNPLUG THE POWER CORD. Using the allen wrench, turn the left rear roller adjust-

ment bolt counterclockwise, and the right bolt clockwise, 1/4 of a turn each. Be careful not to overtighten the walking belt. Plug in the power cord, insert the safety key and run the treadmill for a few minutes. Repeat until the walking belt is centered.

C.If the walking belt slips when walked on, first remove the safety key and UNPLUG THE POWER CORD, Using the allen wrench, turn both rear roller adjustment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tight-ened, you should be able to lift each side of the walking belt 3-4 inches off the walking platform. The cen- ter of the walking belt should just touch the walking plat- form. Be careful to keep the walking belt centered. Plug in the power cord, insert the safety key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

10

Image 10
Contents SEARS, Roebuck and CO., Hoffman ESTATES, IL Table of Contents Full 90 DAY WarrantyImportant Safety Precautions Front Before YOU BeginBack Right Side Assembly Plugging the Power Cord Operation and AdjustmentApplying Silicone Lubricant Turning Power on Diagramofthe ConsoleInstalling Batteries Controlling the SpeedTurning the Power OFF InclineadjustmentMotivational Fitness Monitor Symptom the Power Turns OFF During USE Symptom the Power does not Turn onSymptom the Pulse Earclip does not Function Properly Symptomthe Walkingbeltslowswhenwalkedon If the walking belt has shifted to the left, first removeStorage Unconditioned Conditioned Training Zone AGE BEATS/MIN Conditioning GuidelinesExercise Intensity Workout GuidelinesSuggested Stretches Inner Thigh StretchPart LIST---Model Exploded DRAWING.--Model No Sears Retail Stores Sold by SEARS, Roebuck and CO., Hoffman ESTATES, IL