WIRING
WIRING INSTRUCTIONS (OUTSIDE OF HOUSING)
BNC
(Large) Power
(Small) Alarms
Wiring Color Code Power and Control Inputs
POWER
1 | Camera Power (24 VAC) | Red |
2 | Camera Power (24 VAC) | Orange |
|
|
|
3 | Heater and Blower Power (24 VAC) | Yellow |
|
|
|
4 | Heater and Blower Power (24 VAC) | Green |
|
|
|
CONTROL
1 | Alarm 1 | Blue |
2 | Alarm 2 | Violet |
|
|
|
3 | Alarm 3 | Gray |
|
|
|
4 | Common | White |
|
|
|
If you wish to provide a single power transformer it is recommended that:
1.Be certain that you know the total power consumption of the housing Heater (25 watts) + Blower (1 watt) + camera pan/tilt (25 watts).
2.Check the supplied wiring chart (see below) to be sure that you have the proper gauge wire for the distance that you intend to run your power wires.
3.Bring power to the 3 and 4 position of the power connector (yellow and green wire).
4.Jumper from the 1stposition to the 3 rdposition and from the 2nd position to the 4th position of the terminal block.
Be careful not to short between the yellow and green wires.
| Green | ||
Add 2 jumpers for |
| Yellow | |
single power input | Wires from |
|
|
|
| ||
| Dome |
|
|
|
|
|
|
|
|
|
|
AC |
| |
24V | Orange | |
Power | ||
| ||
Supply | Red | |
Side | ||
|
WIRING INSTRUCTIONS (INSIDE OF HOUSING)
1.The internal power supply provides 12Vdc power.
2.Plug in right angle power plug to back of camera; plug provides 12Vdc to camera.
| + | 12DC | – | Make all connections | |
|
| to the camera. | |||
|
|
|
|
| |
OPTIONAL |
|
|
| ||
1 |
| Alarm 1 |
|
| Blue |
|
|
|
|
|
|
2 |
| Alarm 2 |
|
| Violet |
|
|
|
|
|
|
3 |
| Alarm 3 |
|
| Gray |
4 |
| Common |
|
| White |
|
|
|
|
|
|
NOTE: The total power consumption for the heater and blower, PLUS the camera you choose, need to be added together.
In this example, a 60VA AC24V is required.
24V AC Wiring Distances
The following are the recommended maximum distances for 24 VAC with a 10% voltage drop (10% is generally the maximum allowable voltage drop for AC powered devices).
|
|
|
| Wire Gauge |
|
|
|
|
| |
Total vA | 22 | 20 | 18 | 16 | 14 | 12 | 10 |
| load | |
consumed |
| |||||||||
| 5.5 | 250 | 400 | 600 | 960 | - | - | - |
| to |
| transformer | |||||||||
| 10 | 120 | 180 | 300 | 480 | 800 | 1300 | - |
| |
|
| |||||||||
| 20 | 89 | 141 | 225 | 358 | 571 | 905 | 1440 |
|
|
| 30 | 65 | 90 | 130 | 225 | 350 | 525 | 830 |
| from |
| 40 | 44 | 70 | 112 | 179 | 285 | 452 | 720 |
| |
| distance | |||||||||
60 | 29 | 47 | 75 | 119 | 190 | 301 | 480 |
| ||
50 | 35 | 56 | 90 | 143 | 228 | 362 | 576 |
| load | |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| to |
|
|
|
|
|
|
|
|
|
| |
| 70 | 25 | 40 | 64 | 102 | 163 | 258 | 411 |
| Maximum |
| 80 | 31 | 34 | 55 | 85 | 140 | 215 | 340 |
| former |
|
|