Sony BRCSDP16 instruction manual Wiring Instructions Outside of Housing

Page 3

WIRING

WIRING INSTRUCTIONS (OUTSIDE OF HOUSING)

BNC

(Large) Power

(Small) Alarms

Wiring Color Code Power and Control Inputs

POWER

1

Camera Power (24 VAC)

Red

2

Camera Power (24 VAC)

Orange

 

 

 

3

Heater and Blower Power (24 VAC)

Yellow

 

 

 

4

Heater and Blower Power (24 VAC)

Green

 

 

 

CONTROL

1

Alarm 1

Blue

2

Alarm 2

Violet

 

 

 

3

Alarm 3

Gray

 

 

 

4

Common

White

 

 

 

If you wish to provide a single power transformer it is recommended that:

1.Be certain that you know the total power consumption of the housing Heater (25 watts) + Blower (1 watt) + camera pan/tilt (25 watts).

2.Check the supplied wiring chart (see below) to be sure that you have the proper gauge wire for the distance that you intend to run your power wires.

3.Bring power to the 3 and 4 position of the power connector (yellow and green wire).

4.Jumper from the 1stposition to the 3 rdposition and from the 2nd position to the 4th position of the terminal block.

Be careful not to short between the yellow and green wires.

 

Green

Add 2 jumpers for

 

Yellow

single power input

Wires from

 

 

 

 

 

Dome

 

 

 

 

 

 

 

 

 

 

AC

 

24V

Orange

Power

 

Supply

Red

Side

 

WIRING INSTRUCTIONS (INSIDE OF HOUSING)

1.The internal power supply provides 12Vdc power.

2.Plug in right angle power plug to back of camera; plug provides 12Vdc to camera.

 

+

12DC

Make all connections

 

 

to the camera.

 

 

 

 

 

OPTIONAL

 

 

 

1

 

Alarm 1

 

 

Blue

 

 

 

 

 

 

2

 

Alarm 2

 

 

Violet

 

 

 

 

 

 

3

 

Alarm 3

 

 

Gray

4

 

Common

 

 

White

 

 

 

 

 

 

NOTE: The total power consumption for the heater and blower, PLUS the camera you choose, need to be added together.

In this example, a 60VA AC24V is required.

24V AC Wiring Distances

The following are the recommended maximum distances for 24 VAC with a 10% voltage drop (10% is generally the maximum allowable voltage drop for AC powered devices).

 

 

 

 

Wire Gauge

 

 

 

 

 

Total vA

22

20

18

16

14

12

10

 

load

consumed

 

 

5.5

250

400

600

960

-

-

-

 

to

 

transformer

 

10

120

180

300

480

800

1300

-

 

 

 

 

20

89

141

225

358

571

905

1440

 

 

 

30

65

90

130

225

350

525

830

 

from

 

40

44

70

112

179

285

452

720

 

 

distance

60

29

47

75

119

190

301

480

 

50

35

56

90

143

228

362

576

 

load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to

 

 

 

 

 

 

 

 

 

 

 

70

25

40

64

102

163

258

411

 

Maximum

 

80

31

34

55

85

140

215

340

 

former

 

 

Image 3
Contents BRCSDP16 Electrical Specifications Installing the Housing AssemblyPreparing Pendant Mount Model Wiring Instructions Outside of Housing WiringInstalling the Camera Unpacking Important SafeguardsSafety Precautions Service