ProForm PFTL99707.0 user manual Problem The walking belt slows when walked on

Page 23

Remove the three 3/4" Screws (12) and carefully pivot the Hood (61) off.

12

61

Locate the Reed Switch (71) and the Magnet (50) on the left side of the Pulley (51). Turn the Pulley until the Magnet is aligned with the Reed Switch.

Make sure that the gap between the Magnet and the Reed Switch is about 1/8 in. (3 mm). If nec- essary, loosen the 3/4" Reed Switch Screw (15), move the Reed Switch slightly, and then retighten the Screw. Reattach the Hood (not shown). If nec- essary, tip down the Uprights (not shown), reattach the Hood Screws (not shown) and raise the Uprights. Run the treadmill for a few minutes to check for a correct speed reading.

1/8 in.

15

50

71

51

Top

View

PROBLEM: The incline of the treadmill does not change correctly

SOLUTION: a. With the key in the console, press one of the Incline buttons. While the incline is changing, re- move the key. After a few seconds, re-insert the key. The treadmill will automatically rise to the maximum incline level and then return to the minimum level. This will recalibrate the incline system.

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that meets all of the specifications described on page 12.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be- come damaged. Remove the key and UNPLUG THE POWER CORD. Using the hex key, turn both rear roller bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each edge of the walking belt 2 to 3 in. (5 to 7 cm) off the walking platform. Be careful to keep the walking belt centered. Then, plug in the power cord, insert the key, and run the treadmill for a few minutes. Repeat until the walk- ing belt is properly tightened.

b

2–3 in.

Rear Roller Bolts

c. If the walking belt still slows when walked on, see the front cover of this manual.

23

Image 23
Contents Call TOLL-FREE QUESTIONS?Model No. PFTL99707.0 Serial No Table of Contents Important Precautions Page Before YOU Begin Do not fully fold the Frame yet AssemblyMake sure that the power cord is unplugged Not fully tighten the Bolts yet Careful not to pinch the Upright WireWheel must turn freely Wire Tie Bolts and then tighten them Be careful not to pinch the wiresRaise the Frame 56 to the position shown Page PRE-LUBRICATED Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Console DiagramHOW to USE the Manual Mode HOW to Turn on the PowerAvoid moving Your hands Follow your progress with the displayMeasure your heart rate if desired Stand on Foot railsFollow your progress with the display. See on HOW to USE a Personal Trainer WorkoutSelect a personal trainer workout Press the Start button to start the workoutSelect the iFIT Competition Training Center HOW to USE the Ifit Competition Training CenterEnter user information HOW to USE the Settings ModeSelect the settings mode Measure your heart rate if desired. See onOptional Chest Pulse Sensor Information ModeHOW to Move the Treadmill HOW to Fold and Move the TreadmillHOW to Fold the Treadmill for Storage HOW to Lower the Treadmill for USE Problem The power turns off during use TroubleshootingProblem The walking belt slows when walked on Page Exercise Frequency Exercise GuidelinesExercise Intensity Workout GuidelinesKey No. Qty Description R1107AQty Exploded Drawing A-Model No. PFTL99707.0 R1107A Exploded Drawing B-Model No. PFTL99707.0 R1107A Exploded Drawing C-Model No. PFTL99707.0 R1107A Exploded Drawing D-Model No. PFTL99707.0 R1107A Icon Health & FITNESS, INC., 1500 S W., LOGAN, UT Ordering Replacement PartsLimited Warranty