ProForm 831.297782 user manual Problem The heart rate monitor does not function properly

Page 23

c. If the walking belt slips when walked on, first re- move the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjust- ment bolts clockwise, 1/4 of a turn. When the walking belt is correctly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

c

PROBLEM: The walking belt slows when walked on

SOLUTION: a. Use only a single-outlet surge suppressor that is UL 1449 listed as a transient voltage surge sup- pressor (TVSS). The surge suppressor must have a UL suppressed voltage rating of 400 volts or less and a minimum surge dissipation of 450 joules. The surge suppressor must be electrically rated for 120 volts AC and 15 amps.

b. If the walking belt is overtightened, treadmill perfor- mance may decrease and the walking belt may be per- manently damaged. Remove the key and UNPLUG THE POWER CORD. Using the allen wrench, turn both rear roller adjustment bolts counterclockwise, 1/4 of a turn. When the walking belt is properly tightened, you should be able to lift each side of the walking belt 3 to 4 inches off the walking platform. Be careful to keep the walking belt centered. Plug in the power cord, insert the key and run the treadmill for a few minutes. Repeat until the walking belt is properly tightened.

b

3ÓÐ4Ó

Rear Roller Adjustment Bolts

c. If the walking belt still slows when walked on, please call our toll-free HELPLINE.

PROBLEM: The heart rate monitor does not function properly

SOLUTION: a. If the heart rate monitor does not function properly, refer to CHEST PULSE SENSOR TROUBLE- SHOOTING on page 7.

b. The CR 2032 battery may need to be replaced.

To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover, turn the cover counterclockwise, and remove it.

Remove the old battery and insert a new CR 2032 battery, making

 

 

 

 

sure that the battery is turned so the writing is on top. Make sure that

 

 

 

 

the rubber gasket is in place in the sensor unit. Replace the battery

 

CR 2032

 

cover and turn it clockwise to close it.

 

Battery

 

 

 

 

 

 

 

 

 

 

 

 

Rubber

 

 

Gasket

 

 

 

 

 

 

 

 

 

 

 

23

Image 23
Contents SEARS, Roebuck and CO., Hoffman ESTATES, IL Model No Serial NoImportant Precautions Table of ContentsThere is one Left Right Side Before YOU BeginPhillips AssemblyAssembly requires the included allen wrench Page Chest Pulse Sensor TROUBLE-SHOOTING HOW to USE the Chest Pulse SensorHOW to PUT on the Chest Pulse Sensor Care and MaintenanceBattery ¥ The CR 2032 battery may need to be replacedPerformant Lubetm Walking Belt Operation and AdjustmentHOW to Plug in the Power Cord Features of the Console Diagram of the ConsoleMake sure that Position On/off switch is ÒonÓ position HOW to Turn on the PowerHOW to USE the Manual Mode DISTANCE/LAPS CALS./FAT CalsPress the Start button to start the program HOW to USE the Speed ProgramsSelect the desired speed program Select the desired heart rate program HOW to USE the Heart Rate ProgramsSelect the Fitness Test program HOW to USE the Fitness Test ProgramFollow your progress with the LED track Treadmill is set at 1.5%. Remove the keyPage Hold down STOP/PAUSE button for two Seconds HOW to Create a Custom ProgramInsert the key into the console Select one of the custom programsPress the Start button HOW to USE a Custom ProgramWhen the program is completed, remove the key HOW to Select the Information ModeHOW to Fold the Treadmill for Storage HOW to Fold and Move the TreadmillHOW to Adjust the Firmness of the Walking Platform HOW to Lower the Treadmill for USE HOW to Move the TreadmillProblem The power turns off during use Maintenance and TROUBLE-SHOOTINGCR 2032 battery may need to be replaced Problem The heart rate monitor does not function properlyWorkout Guidelines Conditioning GuidelinesExercise Intensity Suggested Stretches Key No. Qty Description Part LISTÑModel No8Ó White Wire, Male/Female Page Exploded DRAWINGÑModel No SEARS, Roebuck and CO., Dept WA, Hoffman ESTATES, IL Full 90 DAY WarrantyModel No