Seiko S141 manual Memory Recall When the Stopwatch is Measuring, Memory Capacity Indicator

Page 4

When the stopwatch is reset while the block memory mode is selected, a new “block number” is assigned to the next sequence of data.

Block number

A block of data with a block number is automatically accompanied by the starting time and date of measurement, which is convenient for easy data management.

*A block of data contains at least three data components; block number, measured lap/split time(s), starting time and date. If more than one block of data is stored in memory, the memory may reach a capacity limit even before the total number of lap/split time measurement totals to 300.

1.MEMORY RECALL WHEN THE STOPWATCH IS STOPPED OR RESET

￿With each press of “C,” the data is recalled chronologically (starting from the first/oldest data in block “1”). Ex.: When the stopwatch is reset to “00” in block 4

Reset

Start time & date

Fastest lap time

Split & lap times

Stop time

 

 

(block 1)

 

 

 

(block 1)

 

(block 1)

(block 1)

C

Block number

Date

Fastest lap number

Lap/Split number Split time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿

￿

￿

￿

￿

Data of

￿

Data of

block 2

block 3

 

 

 

 

 

 

￿

 

 

 

 

 

 

 

 

Starting time

Fastest lap time

 

 

 

 

 

*The data can be recalled successively by keeping “C” pressed.

*To stop the recall of the data when the stopwatch is stopped, press “A”, “B” or “D.” To stop the recall of the data when the stopwatch is reset, press “A” or “D.”

2.MEMORY RECALL WHEN THE STOPWATCH IS MEASURING

￿With each press of “C,” the data is recalled starting from the last (newest) data.

Ex.: When the measurement of the third split/lap time in block “4” has been completed

Fastest lap time

(block 4)

Fastest lap number

Split/lap 3

￿

 

￿

Split/lap 3

￿

Split/lap 2

￿

Split/lap 1

￿

(block 4)

 

(block 4)

(block 4)

(block 4)

 

 

 

 

 

 

 

 

 

 

 

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data of block 3

￿

Data of block 2

￿

Data of block 1

Accumulated elapsed time

*The data can be recalled successively by keeping “C” pressed.

*To measure the lap time and split time while the stored data are recalled, operate the buttons as follows.

Press “B” to measure new lap time and split time. Press “A” to stop the measurement.

Press “D” to return to the measurement mode.

3.MEMORY CAPACITY INDICATOR

￿ The number of data stored in memory is displayed graphically by the memory capacity indicator.

￿ Each segment of the bar corresponds to 30 data.

*When no segment is displayed, the stored data is less than 30.

￿When the memory reaches its full capacity, all the segments of the bar are displayed.

* The 301st data and those measured thereafter will be displayed but will not be stored in memory for later recall.

￿ While the data is recalled, a segment of the bar flashes to indicate the measurement order of the data being recalled.

￿ A block of data contains at least three data components; block number, measured lap/split time, starting time and date. If more than one block of data is stored in memory, the memory may reach a capacity limit even before the total number of lap/split time measurement totals to 300.

4.HOW TO CLEAR THE STORED DATA

￿Once the following steps are taken, all the stored data are erased from memory. The stored data cannot be erased one by one or block by block.

￿Before clearing the data, check that the stopwatch is reset to “00.”

1.Press “C” to show the MEMORY RECALL display.

2.Keep “B” pressed for more than 1.5 seconds.

*While the button is kept pressed, the display shown at right appears with warning beeps.

*After 1.5 seconds, all the stored data is erased from memory with a long beep. Then, the initial measurement display is shown.

*Unless “B” is kept pressed for more than 1.5 seconds, the stored data will not be erased from memory.

[ Number of data in memory ]

F

291~300

When the number of

 

270~290

 

stored measurements

￿

240~269

exceeds 290, the letter

210~239

"F" starts flashing.

180~209

When the memory is at

 

 

150~179

its full capacity, the

 

120~149

letter "F" stops flashing

 

and remains displayed.

 

90~119

 

 

 

60~ 89

 

E

30~ 59

 

BC

4

Image 4
Contents Features Adjusting the Contrast on the Display TIME/CALENDAR SettingStopwatch Memory Recall Function Single Memory Mode Memory Recall Function Block Memory ModeMemory Recall When the Stopwatch is Stopped or Reset SPLIT/LAP Time MeasurementMemory Capacity Indicator Memory Recall When the Stopwatch is MeasuringHOW to Clear the Stored Data Battery Change SpecificationsHOW to USE the STROKE/FREQUENCY Measuring Function STROKE/FREQUENCY Measurement