Seiko 7T82 manual Specifications

Page 14

English

SPECIFICATIONS

1

Frequency of crystal oscillator

32,768 Hz (Hz = Hertz … Cycles per second)

2

Loss/gain (monthly rate)

± 15 seconds at normal temperature range (5 ºC ~ 35 ºC)

3

Operational temperature range

–10 ºC ~ +60 ºC

4

Driving system

Step motor, 4 pieces

5

Display system

 

 

Time/calendar

Hour, minute and small second hands

 

 

Date is displayed in numerals.

 

Stopwatch

STOPWATCH 1/100-second hand (0.1 second/ 360 degrees)

 

 

STOPWATCH 1/10-second hand (1 second/ 360 degrees)

 

 

STOPWATCH second hand (60 seconds/ 360 degrees)

 

 

STOPWATCH minute hand (40 minutes/ 240 degrees)

6

Battery

SEIKO SR927W, 1 piece

7

Battery life

Approximately 3 years

 

 

If the stopwatch is used for longer than 2 hours a day, the battery

 

 

life may be shorter than the specified period.

8

Battery life indicator

 

9

IC (Integrated Circuit)

C-MOS-IC, 1 piece

* The specifications are subject to change without prior notice for product improvements.

26

Image 14 Seiko 7T82 manual Specifications
Contents Page Contents Stopwatch FeaturesTIME/CALENDAR How to lock the crown HOW to Operate the Screw Down CrownHow to unlock the crown Screw Down CrownTime and Calendar Setting EnglishStopwatch Hand Position Adjustment Second hands turn a full circleRemarks on the Stopwatch minute hand movement HOW to USE the StopwatchHow to read the stopwatch hands While the Stopwatch hands are stopped How to reset the stopwatchWhile the Stopwatch hands are moving Watch Hand Movement How to view the demonstrationDemonstration Functon of the Stop TachymeterTelemeter To measure the hourly rate of operationBattery life indicator Battery ChangeHOW to USE the Telemeter StartNecessary Procedure After Battery Change HOW to Reset the ICTroubleshooting Trouble Possible causesSpecifications